Sunday, April 4, 2010

Hybrid server monitoring


Current trends toward convergence tightly link networking, storage and system performance. In a converged environment, system administrators need to be aware of network traffic linking applications, storage and users in order to avoid performance problems. The dynamic application environment created virtual machine migration, scale out storage and elastic service pools requires that server administrators be aware of network I/O in order to optimize performance and avoid creating problems through poor workload placement choices.

Server operating systems and hardware integrate the instrumentation needed to monitor CPU, memory and disk performance. However, server network adapters typically lack the hardware support needed for traffic monitoring, leaving system administrators with a very limited view of server network I/O. Without hardware support, the network monitoring tools that are available to system administrators are typically used only for troubleshooting since using the tools operationally would adversely impact server performance.

Solving the problem of poor server network visibility requires a broader perspective. Depending on the data center network topology, each server is attached to a blade, top of rack (ToR) or an end of row (EoR) switch. The diagram above illustrates the one-to-one relationship between network adapter and the switch connecting the server to storage and networking resources. Monitoring traffic on a server's switch port provides a complete picture of server network I/O.

Switch vendors recognize the need for network-wide visibility and most have implemented hardware support for the sFlow standard in their data center switches. Combining performance metrics from the server with network visibility from the adjacent switch creates a hybrid monitoring solution that exploits the strengths of existing server and switch instrumentation to provide a complete picture of system performance.

Similar challenges exist in virtual server environments. The integration of sFlow traffic monitoring in the virtual switch (e.g. Xen Cloud Platform) with system performance metrics obtained from virtual machines provides a complete picture of cloud performance. The emerging VEPA standard allows much of the virtual switch functionality to be offloaded from the server software to the adjacent physical switch hardware. VEPA will be a firmware upgrade for most switches so selecting a switch with sFlow support today provides visibility into physical server network I/O and also provides an upgrade path to extend visibility into the virtualization layer as VEPA becomes available.

One challenge remains to widely implementing this hybrid monitoring strategy. Currently, performance monitoring of servers is highly fragmented. Each server hardware, operating system, and system management vendor creates their own agents and software for performance monitoring, none of which interoperate. The emerging sFlow host and power extensions define standard export formats so that performance management tools can easily combine network and server measurements to build a complete picture of data center performance.

Saturday, October 17, 2009

SR-IOV


The diagram (source Intel: Virtual Machine Direct Connect (VMDc)) illustrates the close relationship between the network adapter and the virtual switch in providing networking to virtual machines. Currently most virtual server systems use a software virtual switch (vSwitch) to share access to the network adapter among the virtual machines (VMs).

The Single Root I/O Virtualization (SR-IOV) standard being implemented by 10G network adapter vendors provides hardware support for virtualization, allowing virtual machines to directly share the network adapter without involving the software virtual switch. Hardware sharing improves performance and frees CPU cycles to be used by the virtual machines. Software is still needed to configure and manage the switching function on the network adapter and integrate it with the management of the virtual machines. Virtual switch software is evolving, offloading performance critical functions to the network adapter, while continuing to provide the management interface.

Maintaining visibility and control of the edge is a critical component of an effective data center management strategy. Since virtual switches provide the first layer of switching in a virtualized environment, they comprise the network edge. Integrating the virtual switches into the overall network management system is essential.

Previously, the role of the VEPA protocol in integrating software virtual switches with hardware switches was discussed. VEPA support in the network adapter offers integration between a hardware switch and the network adapter. Most switch vendors support sFlow for traffic monitoring, and the combination of sFlow and VEPA would provide visibility and control of virtual machine traffic.

Ultimately, the evolving functionality of the network adapter/virtual switch is likely to deliver the visibility, performance, security and quality of service capabilities needed from the network edge. This trend is illustrated by the roadmap for the Open vSwitch, which includes support for both sFlow and SR-IOV on its roadmap, along with OpenFlow for control of the edge.

Wednesday, October 14, 2009

VEPA


A virtual switch is a software component of a virtual server, providing network connectivity to virtual machines (VMs). The challenge with virtual switches is integrating them into the rest of the network in order to maintain visibility and control.

The diagram shows how the emerging VEPA (Virtual Ethernet Port Aggregator) standard addresses this challenge by ensuring that packets from the virtual machines connected to the virtual switch (shown in green) also pass through an adjacent hardware switch (Bridge). In a blade server, the adjacent hardware switch would be the blade switch. If stand-alone servers are used, then the adjacent hardware switch would be the top of rack switch.

Passing traffic through the hardware switch offloads tasks such as rate limiting and access control lists (ACLs), simplifying the virtual switch and freeing CPU cycles that can be used by the virtual machines.

The sFlow standard is widely supported by switch vendors. Selecting blade switches and top of rack switches with sFlow and VEPA support will offer visibility and control of the network edge.