Friday, July 31, 2020

Using sFlow to monitor dropped packets

Visibility into dropped packets describes instrumentation, recently added to the Linux kernel, that provides visibility into packets dropped by the kernel data path on a host, or dropped by a switch ASIC when packets are forwarded in hardware. This article describes integration of drop monitoring in the open source Host sFlow agent and inclusion of drop reporting as part of industry standard sFlow telemetry.

Extending sFlow to provide visibility into dropped packets offers significant benefits for network troubleshooting, providing real-time network-wide visibility into the specific packets that were dropped as well the reason the packet was dropped. This visibility instantly reveals the root cause of drops and the impacted connections.

Packet discard monitoring complements sFlow's existing counter polling and packet sampling mechanisms and shares a common data model so that all three sources of data can be correlated.  For example, if packets are being discarded because of buffer exhaustion, the discard records don't necessarily tell the whole story. The discarded packets may represent mice flows that are victims of an elephant flow. Packet samples will reveal the traffic that isn't being dropped and provide a more complete picture. Counter data adds additional information such as CPU load, interface speed, link utilization, packet and discard rates that further completes the picture.

The following steps build the Host sFlow agent with drop monitoring on an Ubuntu 20 system (a Linux 5.4 kernel or newer is required):
git clone https://github.com/sflow/host-sflow
cd host-sflow
make FEATURES="HOST PCAP DROPMON"
sudo make install
sudo make schedule
Next, edit the /etc/hsflowd.conf file, in this example, directing sFlow to be sent to a collector at 192.168.1.242, enabling packet sampling on host adapter enp0s3, and enabling drop monitoring:
sflow {
  collector { ip=192.168.1.242 }
  pcap { dev = enp0s3 }
  dropmon { group = 1 start = on }
}
Start the agent:
sudu systemctl enable hsflowd
sudo systemctl start hsflowd
Build the latest version of sflowtool on the collector host (192.168.1.242):
git clone https://github.com/sflow/sflowtool
cd sflowtool
./boot.sh
./configure
make
sudo make install
Now run sflowtool to receive and decode the sFlow telemetry stream:
sflowtool
The following example shows the output for a discarded TCP packet:
startSample ----------------------
sampleType_tag 0:5
sampleType DISCARD
sampleSequenceNo 20
sourceId 0:1
dropEvents 0
inputPort 1
outputPort 0
discardCode 289
discardReason unknown_l4
discarded_flowBlock_tag 0:1
discarded_flowSampleType HEADER
discarded_headerProtocol 1
discarded_sampledPacketSize 54
discarded_strippedBytes 0
discarded_headerLen 54
discarded_headerBytes 00-00-00-00-00-00-00-00-00-00-00-00-08-00-45-00-00-28-00-00-40-00-40-06-3C-CE-7F-00-00-01-7F-00-00-01-04-05-04-39-00-00-00-00-14-51-E2-8A-50-14-00-00-B2-B4-00-00
discarded_dstMAC 000000000000
discarded_srcMAC 000000000000
discarded_IPSize 40
discarded_ip.tot_len 40
discarded_srcIP 127.0.0.1
discarded_dstIP 127.0.0.1
discarded_IPProtocol 6
discarded_IPTOS 0
discarded_IPTTL 64
discarded_IPID 0
discarded_TCPSrcPort 1029
discarded_TCPDstPort 1081
discarded_TCPFlags 20
endSample   ----------------------
The sflowtool -T option converts the discarded packet records into PCAP format so that they can be decoded by packet analysis tools such as Wireshark and tcpdump:
sflowtool -T | tshark -r -
   12  22.000000 192.168.1.242 → 192.168.1.87 TCP 78 65527 → 80 [SYN] Seq=0 Win=65535 Len=0 MSS=1460 WS=64 TSval=1324841769 TSecr=0 SACK_PERM=1
The article sFlow to JSON uses Python examples to demonstrate how sflowtool's ability to convert sFlow records into JSON can be used for further analysis.

Thursday, July 16, 2020

Visibility into dropped packets

Dropped packets have a profound impact on network performance and availability. Packet discards due to congestion can significantly impact application performance. Dropped packets due to black hole routes, expired TTLs, MTU mismatches, etc. can result in insidious connection failures that are time consuming and difficult to diagnose.

Devlink Trap describes recent changes to the Linux drop monitor service that provide visibility into packets dropped by switch ASIC hardware. When a packet is dropped by the ASIC, an event is generated that includes the header of the dropped packet and the reason why it was dropped. A hardware policer is used to limit the number of events generated by the ASIC to a rate that can be handled by the Linux kernel. The events are delivered to userspace applications using the Linux netlink service.

Running the dropwatch command line tool on an Ubuntu 20 system demonstrates the instrumentation:
pp@ubuntu20:~$ sudo dropwatch
Initializing null lookup method
dropwatch> set alertmode packet
Setting alert mode
Alert mode successfully set
dropwatch> start
Enabling monitoring...
Kernel monitoring activated.
Issue Ctrl-C to stop monitoring
drop at: __udp4_lib_rcv+0xae5/0xbb0 (0xffffffffb05ead95)
origin: software
input port ifindex: 2
timestamp: Wed Jul 15 23:57:36 2020 223253465 nsec
protocol: 0x800
length: 128
original length: 243

drop at: __netif_receive_skb_core+0x14f/0xc90 (0xffffffffb05351af)
origin: software
input port ifindex: 2
timestamp: Wed Jul 15 23:57:36 2020 530212717 nsec
protocol: 0x4
length: 52
original length: 52
The dropwatch package also includes the dwdump command, allowing the dropped packets to be analyzed using packet decoding tools such as tshark:
pp@ubuntu20:~$ sudo dwdump | tshark -r -
   12   0.777386 BelkinIn_a8:8a:7d → Spanning-tree-(for-bridges)_00 STP 196 Conf. Root = 61440/4095/24:f5:a2:a8:8a:7b  Cost = 0  Port = 0x8003
   13   2.825301 BelkinIn_a8:8a:7d → Spanning-tree-(for-bridges)_00 STP 196 Conf. Root = 61440/4095/24:f5:a2:a8:8a:7b  Cost = 0  Port = 0x8003
Linux is the base for many open source and commercial network operating systems used today (e.g. SONiC, DENT, Cumulus, EOS, NX-OS, and IOS-XR). A standard interface for monitoring packet drops is an exciting development, allowing Linux based network monitoring agents to collect, export, and analyze drop events to rapidly identify the root cause of dropped packets.

Thursday, January 30, 2020

SAI 1.5

The Open Compute Project (OCP), "is a rapidly growing community of engineers around the world whose mission is to design and enable the delivery of the most efficient server, storage and data center hardware designs available for scalable computing."

The OCP SAI (Switch Abstraction Interface) Project is an important part of the networking effort, defining "a vendor-independent way of controlling forwarding elements, such as a switching ASIC, an NPU or a software switch in a uniform manner." SAI 1.5 Release Notes describe enhancements to existing sFlow API, in particular adding support for the Linux psample netlink channel, see  Linux 4.11 kernel extends packet sampling support. Supporting the standard Linux interface for packet sampling simplifies the implementation of sFlow agents (e.g. Host sFlow) and ensures consistent behavior across hardware platforms to deliver real-time network-wide visibility using industry standard sFlow protocol.

Thursday, August 30, 2018

Northbound Networks Zodiac GX

Mininet is widely used to emulate software defined networks (SDNs). Mininet flow analytics describes how standard sFlow telemetry, from Open vSwitch used by Mininet emulate the network, provides feedback to an SDN controller, allowing the controller to adapt the network to changing traffic, for example, to mitigate a distributed denial of service (DDoS) attack.

Northbound Networks Zodiac GX is an inexpensive open source software based switch that is ideal for experimenting with software defined networking (SDN) in a physical network setting. The small fanless package makes the switch an attractive option for desktop use. The Zodiac GX is also based on Open vSwitch, making it easy to take SDN control strategies developed on Mininet.
Enabling sFlow on the Zodiac GX is easy, navigate to the System>Startup page and add the following line to the end of the startup script (before the exit 0 line):
ovs-vsctl -- --id=@sflow create sflow agent=$OVS_BR target=$IP_CONTROLLER_1 sampling=100 polling=10 -- set bridge $OVS_BR sflow=@sflow
Reboot the switch for the changed to take effect.

Use sflowtool to verify that sFlow is arriving at the controller host and to examine the contents of the telemetry stream. Running sflowtool using Docker is a simple alternative to building the software from sources:
docker run --rm -p 8008:8008 -p 6343:6343/udp sflow/sflowtool
The text output from sflowtool can be piped into scripts to perform basic sFlow analysis.
A graphical sFlow analyzer performs the analysis tasks for you. The screen shot above shows sFlowTrend, a free sFlow analyzer that displays traffic trends. The software can be downloaded and installed or run using Docker:
docker run --rm -p 6343:6343/udp -p 8087:8087 -p 8443:8443 sflow/sflowtrend
The sFlowTrend charts update every minute. This is generally fast enough for human consumption, but real-time, up to the second, visibility is critical for SDN use cases.
The screen shot from Flow Trend shows an up to the second view of traffic. The spike in traffic is due to a 4K video being streamed from YouTube. The following command runs the software:
docker run --rm -p 6343:6343/udp -p 8008:8008 sflow/flow-trend
Flow Trend is an application running on the sFlow-RT real-time analytics platform.
Applications running on the sFlow-RT platform deliver real-time visibility to SDN, DevOps and Orchestration stacks, enabling new classes of performance aware application such as load balancing, DDoS mitigation, and workload placement.

RYU provides a framework that can be used to develop SDN applications in Python. For example, the following command runs the simple learning bridge application that ships with RYU:
docker run -it --rm -p 6633:6633 osrg/ryu ryu-manager --verbose ryu/ryu/app/simple_switch_13.py
As soon as the switch connects to the controller, you should see a flurry of events as the controller programs flows on the Zodiac GX switch.

Faucet is an SDN controller for production networks implemented using RYU. Before we can use Faucet, we need to gather basic OpenFlow information from the switch.
$ ssh -t admin@10.0.0.230 "sudo ovs-ofctl show ovslan"
admin@10.0.0.230's password: 
Password: 
OFPT_FEATURES_REPLY (xid=0x2): dpid:000044d1fa6291b2
n_tables:254, n_buffers:256
capabilities: FLOW_STATS TABLE_STATS PORT_STATS QUEUE_STATS ARP_MATCH_IP
actions: output enqueue set_vlan_vid set_vlan_pcp strip_vlan mod_dl_src mod_dl_dst mod_nw_src mod_nw_dst mod_nw_tos mod_tp_src mod_tp_dst
 1(eth0.1): addr:44:d1:fa:62:91:b2
     config:     0
     state:      STP_FORWARD
     current:    1GB-FD AUTO_NEG
     speed: 1000 Mbps now, 0 Mbps max
 2(eth0.2): addr:44:d1:fa:62:91:b2
     config:     0
     state:      STP_FORWARD
     current:    1GB-FD AUTO_NEG
     speed: 1000 Mbps now, 0 Mbps max
 3(eth0.3): addr:44:d1:fa:62:91:b2
     config:     0
     state:      STP_FORWARD
     current:    1GB-FD AUTO_NEG
     speed: 1000 Mbps now, 0 Mbps max
 4(eth0.4): addr:44:d1:fa:62:91:b2
     config:     0
     state:      STP_FORWARD
     current:    1GB-FD AUTO_NEG
     speed: 1000 Mbps now, 0 Mbps max
 5(eth0.5): addr:44:d1:fa:62:91:b2
     config:     0
     state:      STP_FORWARD
     current:    1GB-FD AUTO_NEG
     speed: 1000 Mbps now, 0 Mbps max
 LOCAL(ovslan): addr:44:d1:fa:62:91:b2
     config:     0
     state:      0
     current:    1GB-FD AUTO_NEG
     speed: 1000 Mbps now, 0 Mbps max
OFPT_GET_CONFIG_REPLY (xid=0x4): frags=normal miss_send_len=0
Connection to 10.0.0.230 closed.
Update August 30, 2018: The only piece of information needed to construct the faucet config file below is the switch dpid. The Zodiac GX uses the MAC address of the switch as the dpid, so you can simply read the MAC address printed on a label on the bottom of the switch.
Now create a directory called faucet that contains the initial Faucet configuration file, faucet.yaml:
vlans:
    office:
        vid: 100
        description: "office network"

dps:
    zodiac:
        dp_id: 0x000044d1fa6291b2
        hardware: "ZodiacGX"
        interfaces:
            1:
                name: "eth0.1"
                description: "port1"
                native_vlan: office
            2:
                name: "eth0.2"
                description: "port2"
                native_vlan: office
            3:
                name: "eth0.3"
                description: "port3"
                native_vlan: office
            4:
                name: "eth0.4"
                description: "port4"
                native_vlan: office
            5:
                name: "eth0.5"
                description: "port5"
                native_vlan: office
            0xfffffffe:
                name: "ovslan"
                description: "local"
                native_vlan: office
Now run Faucet:
docker run -it --rm -v $PWD/faucet/:/etc/faucet/ -v $PWD/faucet/:/var/log/faucet/ -p 6633:6653 -p 9302:9302 faucet/faucet
As soon as the switch connects to the controller, you should see events logged to the faucet.log file in the same directory as the faucet.yaml configuration file.

Faucet Documentation describes how to extend the configuration to include firewall, routing, segmentation, and network function virtualization (NFV) rules to the configuration.

The next step is integrating sFlow analytics with the controller. Writing Applications describes how write sFlow-RT applications use REST API and embedded JavaScript API. The document includes Python examples that could be embedded in RYU controller applications. Alternatively, sFlow-RT's embedded HTTP client can be used to push control actions to an SDN controller, see ONOS measurement based control for an example.

The sFlow telemetry stream contains detailed Open vSwitch performance metrics in addition to flow and interface counter data. The sFlow-RT analytics pipeline can be programmed to generate and push statistics to time series databases and dashboards, see Prometheus and Grafana and InfluxDB and Grafana.

Exporting events using syslog describes how sFlow-RT can be programmed to detect and report on traffic anomalies, sending events to Security Information and Event Management (SIEM) tools, using Splunk and Logstash as examples.

The sflow/sflow-rt Docker image provides a convenient means of developing and deploying sFlow-RT applications alongside the SDN controllers demonstrated in this article.

An important benefit of sFlow telemetry is that it decouples monitoring from the control plane. You are free to change SDN controllers, use distributed routing / switching protocols, move between network operating systems, or build your own control plane while maintaining the same level of visibility. Industry standard sFlow is widely supported by vendors, including: A10, Aerohive, ALUe, Allied Telesis, Arista, Aruba, Big Switch, Broadcom, Cisco, Cumulus, Dell, D-Link, Edge-Core, Extreme, F5, Fortinet, Huawei, IP Infusion, Juniper, Mellanox, Netgear, OpenSwitch, Pica8, Proxim, Quanta, SMC, ZTE, and ZyXEL.

Wednesday, July 11, 2018

sFlow available on Juniper PTX series routers


sFlow functionality introduced on the PTX1000 and PTX10000 platforms—Starting in Junos OS Release 18.2R1, the PTX1000 and PTX10000 routers support sFlow, a network monitoring protocol for high-speed networks. With sFlow, you can continuously monitor tens of thousands of ports simultaneously. The mechanism used by sFlow is simple, not resource intensive, and accurate.  - New and Changed Features

The recent article, sFlow available on Juniper MX series routers, describes how Juniper is extending sFlow support to include routers to provide visibility across their entire range of switching and routing products.

Universal support for industry standard sFlow as a base Junos feature reduces the operational complexity and cost of network visibility for enterprises and service providers. Real-time streaming telemetry from campus switches, routers, and data center switches, provides centralized, real-time, end-to-end visibility needed to troubleshoot, optimize, and account for network usage.

Analytics software is a critical factor in realizing the full benefits of sFlow monitoring. Choosing an sFlow analyzer discusses important factors to consider when selecting from the range of open source and commercial sFlow analysis tools.

Friday, April 6, 2018

sFlow available on Juniper MX series routers

sFlow support on MX Series devices—Starting in Junos OS Release 18.1R1, you can configure sFlow technology (as a sFlow agent) on a MX Series device, to continuously monitor traffic at wire speed on all interfaces simultaneously. The sFlow technology is a monitoring technology for high-speed switched or routed networks.  - New and Changed Features

Understanding How to Use sFlow Technology for Network Monitoring on a MX Series Router lists the following benefits of sFlow Technology on a MX Series Router:
  • sFlow can be used by software tools like a network analyzer to continuously monitor tens of thousands of switch or router ports simultaneously.
  • Since sFlow uses network sampling (forwarding one packet from ‘n’ number of total packets) for analysis, it is not resource intensive (for example processing, memory and more). The sampling is done at the hardware application-specific integrated circuits (ASICs) and hence it is simple and more accurate.
With the addition of the MX series routers, Juniper now supports sFlow across its entire product range:
Universal support for industry standard sFlow as a base Junos feature reduces the operational complexity and cost of network visibility for enterprises and service providers. Real-time streaming telemetry from campus switches, routers, and data center switches, provides centralized, real-time, end-to-end visibility needed to troubleshoot, optimize, and account for network usage.
Analytics software is a critical factor in realizing the full benefits of sFlow monitoring. Choosing an sFlow analyzer discusses important factors to consider when selecting from the range of open source and commercial sFlow analysis tools.

Thursday, July 13, 2017

Linux 4.11 kernel extends packet sampling support

Linux 4.11 on Linux Kernel Newbies describes the features added in the April 30, 2017 release. Of particular interest is the new netlink sampling channel:
Introduce psample, a general way for kernel modules to sample packets, without being tied to any specific subsystem. This netlink channel can be used by tc, iptables, etc. and allow to standardize packet sampling in the kernel commit
The psample netlink channel delivers sampled packet headers along with associated metadata from the Linux kernel to user space. The psample fields map directly into sFlow Version 5 sampled_header export structures:

netlink psamplesFlowDescription
PSAMPLE_ATTR_IIFINDEXinputInterface packet was received on.
PSAMPLE_ATTR_OIFINDEXoutputInterface packet was sent on.
PSAMPLE_ATTR_SAMPLE_GROUPdata sourceThe location within network device that generated packet sample.
PSAMPLE_ATTR_GROUP_SEQdropsNumber of times that the sFlow agent detected that a packet marked to be sampled was dropped due to lack of resources. Agent calculates drops by tracking discontinuities in PSAMPLE_ATTR_GROUP_SEQ
PSAMPLE_ATTR_SAMPLE_RATEsampling_rateThe Sampling Rate specifies the ratio of packets observed at the Data Source to the samples generated. For example a sampling rate of 100 specifies that, on average, 1 sample will be generated for every 100 packets observed.
PSAMPLE_ATTR_ORIGSIZEframe_lengthOriginal length of packet before sampling
PSAMPLE_ATTR_DATAheader<>Header bytes

Linux is widely used for switch network operating systems, including: Arista EOS, Cumulus Linux, Dell OS10, OpenSwitch, SONiC, and Open Network Linux. The adoption of Linux by network vendors and cloud providers is driving increased support for switch hardware by the Linux kernel community.

Hardware support for sFlow packet sampling is widely implemented in switch ASICs, including: Broadcom, Mellanox, Intel, Marvell, Barefoot Networks, Cavium, and Innovium. A standard Linux interface to ASIC sampling simplifies the implementation of sFlow agents (e.g. Host sFlow) and ensures consistent behavior across hardware platforms to deliver real-time network-wide visibility using industry standard sFlow protocol.

Wednesday, July 5, 2017

BGP FlowSpec on white box switch

BGP FlowSpec is a method of distributing access control lists (ACLs) using the BGP protocol. Distributed denial of service (DDoS) mitigation is an important use case for the technology, allowing a targeted network to push filters to their upstream provider to selectively remove the attack traffic.

Unfortunately, FlowSpec is currently only available on high end routing devices and so experimenting with the technology is expensive. Looking for an alternative, Cumulus Linux is an open Linux platform that allows users to install Linux packages and develop their own software.

This article describes a proof of concept implementation of basic FlowSpec functionality using ExaBGP installed on a free Cumulus VX virtual machine.  The same solution can be run on inexpensive commodity white box hardware to deliver terabit traffic filtering in a production network.

First, install latest version of ExaBGP on the Cumulus Linux switch:
curl -L https://github.com/Exa-Networks/exabgp/archive/4.0.0.tar.gz | tar zx
Now define the handler, acl.py, that will convert BGP FlowSpec updates into standard Linux netfilter/iptables entries used by Cumulus Linux to specify hardware ACLs (see Netfilter - ACLs):
#!/usr/bin/python
 
import json
import re
from os import listdir,remove
from os.path import isfile
from subprocess import Popen,STDOUT,PIPE
from sys import stdin, stdout, stderr

id = 0
acls = {}

dir = '/etc/cumulus/acl/policy.d/'
priority = '60'
prefix = 'flowspec'
bld = '.bld'
suffix = '.rules'

def commit():
  Popen(["cl-acltool","-i"],stderr=STDOUT,stdout=PIPE).communicate()[0]

def aclfile(name):
  global dir,priority,prefix,suffix
  return dir+priority+prefix+name+suffix

def handleSession(state):
  if "down" == state:
    for key,rec in acls.items():
      fn = aclfile(str(rec['id']))
      if isfile(fn):
        remove(fn)
      del acls[key]
    commit()

def buildACL(flow,action):
  acl = "[iptables]\n-A FORWARD --in-interface swp+"
  if flow.get('protocol'):
    acl = acl + " -p " + re.sub('[!<>=]','',flow['protocol'][0])
  if flow.get('source-ipv4'):
    acl = acl + " -s " + flow['source-ipv4'][0]
  if flow.get('destination-ipv4'):
    acl = acl + " -d " + flow['destination-ipv4'][0]
  if flow.get('source-port'):
    acl = acl + " --sport " + re.sub('[!<>=]','',flow['source-port'][0])
  if flow.get('destination-port'):
    acl = acl + " --dport " + re.sub('[!<>=]','',flow['destination-port'][0])
  acl = acl + " -j DROP\n"
  return acl

def handleFlow(add,flow,action):
  global id
  key = flow['string']
  if add:
    acl = buildACL(flow,action)
    id = id + 1
    acls[key] = {"acl":acl,"id":id}
    fn = aclfile(str(id))
    f = open(fn,'w')
    f.write(acl)
    f.close()
    commit()
  elif key in acls:
    rec = acls[key]
    fn = aclfile(str(rec['id']))
    if isfile(fn):
      remove(fn)
    del acls[key]
    commit()
  
while True:
  try:
     line = stdin.readline().strip()
     msg = json.loads(line)
     type = msg["type"]
     if "state" == type:
       state = msg["neighbor"]["state"]
       handleSession(state)
     elif "update" == type:
       update = msg["neighbor"]["message"]["update"] 
       if update.get('announce'):
         flow = update["announce"]["ipv4 flow"]["no-nexthop"][0]
         community = update["attribute"]["extended-community"][0]
         handleFlow(True,flow,community)
       elif update.get('withdraw'):
         flow = update["withdraw"]["ipv4 flow"][0]
         handleFlow(False,flow,None)
     else:
       pass
  except IOError:
     pass
Note: This script is a simple demonstration of the concept that has significant limitations: there is no error handling, the only action is to drop traffic, and FlowSpec comparison operators are ignored. The script is is based on the article RESTful control of Cumulus Linux ACLs.

Update July 6, 2017: An improved version of the acl.py script is now available in the ExaBGP repository on GitHub, see flow.py

Next, create the exabgp.conf file:
process acl {
   run ./acl.py;
   encoder json;
}

template {
  neighbor controller {
    family {
      ipv4 flow;
    }
    api speaking {
      processes [ acl ];
      neighbor-changes;
      receive {
         parsed;
         update;
      }
    }
  }
}

neighbor 10.0.0.70 {
  inherit controller;
  router-id 10.0.0.140;
  local-as 65140;
  peer-as 65070;
  local-address 0.0.0.0;
  connect 1179;
}
Finally, run ExaBGP:
sudo env exabgp.daemon.user=root exabgp-4.0.0/sbin/exabgp exabgp.conf
This configuration instructs ExaBGP to connect to the controller, 10.0.0.162, and prepare to receive BGP FlowSpec messages. When a BGP message is received, ExaBGP decodes the message and passes it on in the form of a JSON encoded string to the acl.py program. For example, the following FlowSpec message was sent to block an NTP reflection DDoS attack (traffic from UDP port 123) targeting host 192.168.0.1:
{
 "exabgp": "4.0.0",
 "time": 1498868955.31,
 "host": "tor-router",
 "pid": 3854,
 "ppid": 3849,
 "counter": 6,
 "type": "update",
 "neighbor": {
  "address": {
   "local": "0.0.0.0",
   "peer": "10.0.0.70"
  },
  "asn": {
   "local": "65140",
   "peer": "65070"
  },
  "direction": "receive",
  "message": {
   "update": {
    "attribute": {
     "origin": "igp",
     "as-path": [
      65140
     ],
     "confederation-path": [],
     "local-preference": 100,
     "extended-community": [
      9225060886715040000
     ]
    },
    "announce": {
     "ipv4 flow": {
      "no-nexthop": [
       {
        "destination-ipv4": [
         "192.168.0.1/32"
        ],
        "protocol": [
         "=udp"
        ],
        "source-port": [
         "=123"
        ],
        "string": "flow destination-ipv4 192.168.0.1/32 protocol =udp source-port =123"
       }
      ]
     }
    }
   }
  }
 }
}
The acl.py script wrote the file /etc/cumulus/acl/policy.d/60flowspec1.rules with an iptables representation of the FlowSpec message:
[iptables]
-A FORWARD --in-interface swp+ -p udp -d 192.168.0.1/32 --sport 123 -j DROP
The acl.py script also invoked the cl-acltool command to install the new rule, which can be verified using iptables:
sudo iptables --list FORWARD
Chain FORWARD (policy ACCEPT)
target     prot opt source               destination         
DROP       all  --  240.0.0.0/5          anywhere            
DROP       all  --  loopback/8           anywhere            
DROP       all  --  base-address.mcast.net/4  anywhere            
DROP       all  --  255.255.255.255      anywhere            
DROP       udp  --  anywhere             192.168.0.1          udp spt:ntp
The attack traffic is now dropped by the switch. In a hardware switch, this entry would be pushed by Cumulus Linux into the hardware, filtering the traffic at line rate to provide Terabit traffic filtering.

Wednesday, July 20, 2016

Internet router using Cumulus Linux

Internet router using merchant silicon describes how an inexpensive white box switch running Linux can be used to replace a much costlier Internet router. This article will describe the steps needed to install the software on an x86 based white box switch running Cumulus Linux 3.0.

First, add the Debian Jessie repository:
sudo sh -c 'echo "deb http://ftp.us.debian.org/debian jessie main contrib" > \
/etc/apt/sources.list.d/deb.list'
Next, install Host sFlow, Java, and Bird:
sudo apt-get update
sudo apt-get install hsflowd
sudo apt-get install unzip
sudo apt-get install default-jre-headless
sudo apt-get install bird
Install sFlow-RT (the latest version is available at sFlow-RT.com):
wget http://www.inmon.com/products/sFlow-RT/sflow-rt_2.0-1116.deb
sudo dpkg -i sflow-rt_2.0-1116.deb
Increase the default virtual memory limit for sflowrt (needs to be greater than 1/3 amount of RAM on system to start Java virtual machine, see Giant Bug: Cannot run java with a virtual mem limit (ulimit -v)):
sudo sh -c 'echo "sflowrt soft as 2000000" > \
/etc/security/limits.d/99-sflowrt.conf'
Note: Maximum Java heap memory has a default of 1G and is controlled by settings in /usr/local/sflow-rt/conf.d/sflow-rt.jvm file.

Install the Active Route Manager application:
sudo sh -c "/usr/local/sflow-rt/get-app.sh sflow-rt active-routes"
Cumulus Networks, sFlow and data center automation describes how to configure the sFlow agent (hsflowd). The sFlow collector address should be set to 127.0.0.1.

Finally, configure Bird and sFlow-RT as described in Internet router using merchant silicon.

The instructions were tested on a Cumulus VX virtual machine, but should work on physical switches. Cumulus VX is free and provides a convenient way to try out Cumulus Linux and create virtual networks to test configurations.

If you are going to experiment with the solution on CumulusVX then the following command is needed to enable sFlow traffic monitoring:
sudo iptables -I FORWARD -j NFLOG --nflog-group 1 --nflog-prefix SFLOW
On physical switches the sFlow agent automatically configures packet sampling in the ASIC and is able to monitor all packets (not just the routed packets captured by the iptables command above).

Wednesday, June 15, 2016

Programmable hardware: Barefoot Networks, PISA, and P4

Barefoot Networks recently came out of stealth to reveal their  Tofino 6.5Tbit/second (65 X 100GE or 260 X 25GE) fully user-programmable switch. The diagram above, from the talk Programming The Network Data Plane by Changhoon Kim of Barefoot Networks, shows the Protocol Independent Switch Architecture (PISA) of the programmable switch silicon.
A logical switch data-plane described in the P4 language is compiled to program the general purpose PISA hardware. For example, the following P4 code snippet is part of a P4 sFlow implementation:
table sflow_ing_take_sample {
    /* take_sample > MAX_VAL_31 and valid sflow_session_id => take the sample */
    reads {
        ingress_metadata.sflow_take_sample : ternary;
        sflow_metadata.sflow_session_id : exact;
    }
    actions {
        nop;
        sflow_ing_pkt_to_cpu;
    }
}
Network visibility is one of the major use cases for P4 based switches. Improving Network Monitoring and Management with Programmable Data Planes describes how P4 can be used to collect information about latency and queueing in the switch forwarding pipeline.
The document also describes an architecture for In-band Network Telemetry (INT) in which the ingress switch is programmed to insert a header containing measurements to packets entering the network. Each switch in the path is programmed to append additional measurements to the packet header. The egress switch is programmed to remove the header so that the packet can be delivered to its destination. The egress switch is responsible for processing the measurements or sending them on to analytics software.

In-band telemetry is an interesting example of the flexibility provided by P4 programmable hardware and the detailed information that can be gathered about latency and queueing from the hardware forwarding pipeline. However, there are practical issues that should be considered with this approach:
  1. Transporting measurement headers is complex with different encapsulations for each transport protocol:  Geneve, VxLAN, etc.
  2. Addition of headers increases the size of packets and risks causing traffic to be dropped downstream due to maximum transmission unit (MTU) restrictions.
  3. The number of measurements that can be added by each switch and the number of switches adding measurements in the path needs to be limited.
  4. In-band telemetry cannot be incrementally deployed. Ideally, all devices need to participate, or at a minimum, the ingress and egress devices need to be in-band telemetry aware.
  5. In-band telemetry transports data from the data plane to the control/management planes, providing a potential attack surface that could be exploited by crafting malicious packets with fake measurement headers.
The sFlow architecture provides an out of band alternative for transporting the per packet forwarding plane measurements defined by INT. Instead of adding the measurements to the egress packet, measurements can be attached as metadata to the sampled packets that are handed to the switch CPU. The sFlow agent immediately forwards the additional packet metadata as part of the standard sFlow telemetry stream to a centralized collector. Using sFlow as the telemetry transport has a number of benefits:
  1. Simple to deploy since there is no modification of packets (no issues with encapsulations, MTU, number of measurements, path length, incremental deployment, etc.)
  2. Extensibility of sFlow protocol allows additional forwarding plane measurements to augment standard sFlow measurements, fully integrating the new measurements with sFlow data exported from other switches in the network (sFlow is supported by over 40 switch vendors and is a standard feature of switch ASICs).
  3. sFlow's is a unidirectional telemetry transport protocol originates from the device management plane, can be sent out of band, limiting possible attack surfaces.
The great thing about programmable hardware is that behavior can be modified by changing the software. Implementing out of band telemetry is a matter of combining measurements from the P4 INT code with the P4 sFlow agent code. Compiling and installing out of band sFlow telemetry code reprograms the hardware to implement the new scheme.

The advent of P4 and programmable hardware opens up exciting possibilities for defining additional packet sample metadata, counters, and gauges to augment the sFlow telemetry stream and gain additional insight into the performance of production traffic in large scale, high capacity, networks.

The real-time sFlow streaming telemetry can be used to drive automated controls, for example, to block DDoS attacks, or load balance large "Elephant" flows across multiple paths. Here again P4 combined with programmable hardware makes it possible to create additional control capabilities, for example, to be able to block the large numbers of source addresses involved in a DDoS attack, where sFlow analytics would be used to identify the attackers and their points of ingress and program each of the switches with filters based on their location in the network. The ability to customize the hardware to address specific tasks makes more efficient use of hardware resources than is possible with fixed function device. In this case, defining a specialized DDoS drop table would allow for a much larger number of filters than would be possible with a general purpose ACL table.

Tuesday, September 8, 2015

Cisco adds sFlow support to Nexus 9K series

Cisco adds support for the sFlow standard in the Cisco Nexus 9000 Series 7.0(3)I2(1) NX-OS Release. Combined with the Nexus 3000/3100 series, which have included sFlow support since NX-OS 5.0(3)U4(1),  Cisco now offers cost effective, built-in, visibility across the full spectrum of data center switches.
Cisco network engineers might not be familiar with the multi-vendor sFlow technology since it is a relatively new addition to Cisco products. The article, Cisco adds sFlow support, describes some of the key features of sFlow and contrasts them to Cisco NetFlow.
Nexus 9000 switches can be operated in NX-OS mode or ACI mode:
  • NX-OS mode includes a number of open features such as sFlow, Python, NX-API, and Bash that integrate with an open ecosystem of orchestration tools such as Puppet, Chef, CFEngine, and Ansible. "By embracing the open culture of development and operations (DevOps) and creating a more Linux-like environment in the Cisco Nexus 9000 Series, Cisco enables IT departments with strong Linux skill sets to meet business needs efficiently," Cisco Nexus 9000 Series Switches: Integrate Programmability into Your Data Center. Open APIs are becoming increasingly popular, preventing vendor lock-in, and allowing organizations to benefit from the rapidly increasing range of open hardware and software solutions to reduce costs and increase agility.
  • ACI mode is a closed solution that relies on proprietary hardware and places the switches under the control of Cisco's APIC (Application Policy Infrastructure Controller) - eliminating many of the features, including sFlow, available in NX-OS mode. The ACI solution is more expensive and the closed platform locks customers into Cisco hardware and solutions.
SDN fabric controllers compares tightly coupled (ACI) and loosely federated (NX-OS) approaches to virtualizing data center networking and there are a number of articles on this blog exploring use cases for real-time sFlow analytics in the data center.

Wednesday, April 1, 2015

Big Tap sFlow: Enabling Pervasive Flow-level Visibility


Today's Big Switch Networks webinar, Big Tap sFlow: Enabling Pervasive Flow-level Visibility, describes how Big Switch uses software defined networking (SDN) to control commodity switches and deliver network visibility. The webinar presents a live demonstration showing how real-time sFlow analytics is used to automatically drive SDN actions to provide a "smarter way to find a needle in a haystack."

The video presentation covers the following topics:

  • 0:00 Introduction to Big Tap
  • 7:00 sFlow generation and use cases
  • 12:30 Demonstration of real-time tap triggering based on sFlow

The webinar describes how the network wide monitoring provided by industry standard sFlow instrumentation complements the Big Tap SDN controller's ability to capture and direct packet selected packet streams to visibility tools.

The above slide from the webinar draws an analogy for the role that sFlow plays in targeting the capture network to that of a finderscope, the small, wide-angle telescope used to provide an overview of the sky and guide the telescope to its target. Support for the sFlow measurement standard is built into commodity switch hardware and is enabled on all ports in the capture network to provide a wide angle view of all traffic in the data center. Once suspicious activity is detected, targeted captures can be automatically triggered using Big Tap's REST API.
Blacklists are an important way in which the Internet community protects itself by identifying bad actors. Incorporating blacklists in traffic monitoring can be a useful way to find hosts on a network that have been compromised. If a host interacts with addresses known to be part of a botnet for example, then it raises the concern that the host has been compromised and is itself a member of the botnet.

Black lists can be very large, larger lists can exceed a million addresses. Switches don't have the resources to match traffic against such large lists. However, sFlow shifts analysis from the switches to external software which can easily handle to task of matching traffic against large lists. The live demonstration uses InMon's sFlow-RT real-time analytics software to match sFlow data against a large blacklist.  When a match is detected the Big Tap controller is programmed via a REST API call to capture all the packets from the suspected hosts and stream them to Wireshark for further investigation.

Monday, December 1, 2014

Open vSwitch 2014 Fall Conference


Open vSwitch is an open source software virtual switch that is popular in cloud environments such as OpenStack. Open vSwitch is a standard Linux component that forms the basis of a number of commercial and open source solutions for network virtualization, tenant isolation, and network function virtualization (NFV) - implementing distributed virtual firewalls and routers.

The recent Open vSwitch 2014 Fall Conference agenda included a wide variety speakers addressing a range of topics, including: large scale operation experiences at Rackspace, implementing stateful firewalls, Docker networking,  and acceleration technologies (Intel DPDK and Netmap/VALE).

The video above is a recording of the following sFlow related talk from the conference:
Traffic visibility and control with sFlow (Peter Phaal, InMon)
sFlow instrumentation has been included in Open vSwitch since version 0.99.1 (released 25 Jan 2010). This talk will introduce the sFlow architecture and discuss how it differs from NetFlow/IPFIX, particularly in regards to delivering real-time flow analytics to an SDN controller. The talk will demonstrate that sFlow measurements from Open vSwitch are identical to sFlow measurements made in hardware on bare metal switches, providing unified, end-to-end, measurement across physical and virtual networks. Finally, Open vSwitch / Mininet will be used to demonstrate Elephant flow detection and marking using a combination of sFlow and OpenFlow.
Slides and videos for all the conference talks will soon be available on the Open vSwitch web site.

Saturday, February 22, 2014

Dell, Cumulus, Open Source, Open Standards, and Unified Management


On Thursday, at Network Field Day 7, Arpit Joshipura described Dell's networking strategy. He started by polling the delegates to see which topics were most on their mind.
The first topic raised by many of the delegates was the recently announced Dell/Cumulus partnership (listed as Open NW on the white board), see Dell Unlocks New Era for Open Networking, Decouples Hardware and Software. Next on the list was an interest in Dell's Open Source networking strategy, understanding Dell's Differentiation strategy, and plans for L3.
Dell's open networking strategy is described at time marker 14:55 in the video. Dell was one of the first vendors to move to merchant silicon, now they are opening up the switch platform, allowing customers to choose from standard merchant silicon based switch platforms (Broadcom, Intel) and switch software (currently FTOS / Cumulus).

Arpit suggests that customers will choose Cumulus Linux as the operating system for the layer 3 features and because they can use the same expertise and tools (Puppet, Chef etc.) to manage Linux servers and the switches connecting them. He also suggested that customers would choose FTOS for legacy networks and layer 2 features. Support for the Open Networking Install Environment (ONIE) allows customers to load different switch operating systems on the hardware. This is the same model as Dell uses when selling servers, allowing customers to choose hardware (Intel/AMD), software (Windows, SUSE, Red Hat), and obtain support from Dell. Arpit summarizes the strategy, "Michael Dell did this on PCs, he did it on servers and I think we are in the best position to do it for networking."
The recent talk, It Ain't Software Defined until you Unbundle the Platform, by JR Rivers Co-Founder/CEO of Cumulus Networks, at the Silicon Valley Software Defined Networking Group captures the vision. While the number of hardware and software choices is currently limited, both the Dell and Cumulus talks are clear that Cumulus Linux is the first of many software choices, other likely future candidates include: Broadcom Fastpath, Big Switch's Switch Light Linux, Pluribus OpenNetvisor, Pica8 PicOS, etc. On the hardware front, expect a greater variety of switching platforms, ranging from familiar top of rack configurations to others that look more like servers with the CPU and memory resources to implement application functions like content distribution, caching, load balancing etc.

Open switching platforms and merchant silicon are part of a set of accelerating trends that are driving toward a common set of standards and APIs that deliver the data center wide visibility and control needed to deliver agile, self optimizing, software defined data centers - see Drivers for growth.

Monday, August 26, 2013

NSX network gateway services

Figure 1: VMware NSX network gateway services partners
VMware recently released the list of Network Gateway Services (top of rack switch) partners. All but one of these vendors supports the sFlow standard for network visibility across their full range of data center switches (Arista Networks, Brocade Networks, Dell Systems, HP and Juniper Networks). The remaining vendor, Cumulus Networks, has developed a version of Linux that runs on merchant silicon based hardware platforms. Merchant silicon switch ASICs include hardware support for sFlow and it is likely that future versions of Cumulus Linux will expose this capability.
Figure 2: Network gateway services / VxLAN tunnel endpoint (VTEP)
Figure 2 from Network Virtualization Gets Physical shows the role that top of rack switches play in virtualizing physical workloads (e.g. servers, load balancers, firewalls, etc.). Essentially, the physical top of rack switch provides the same services for the physical devices as Open vSwitch in the hypervisor provides for virtual machines. The OVSDB protocol, described in the Internet Draft (ID) The Open vSwitch Database Management Protocol, allows the NSX controller to configure physical and virtual switches to set up the VxLAN tunnels used to overlay the virtual networks over the underlying physical network.

The Open vSwitch also supports the sFlow standard, providing a common monitoring solution for virtual switches and top of rack switches. In addition, core switches and routers from the listed partner vendors (and many other switch vendors) also implement sFlow, offering complete end to end visibility into traffic flowing on the virtualized and physical networks.

The packet header export mechanism in sFlow is uniquely suited to monitoring tunneled traffic, see Tunnels, exposing inner and outer addresses and allowing monitoring tools to trace virtualized traffic as it flows over the physical fabric, see Down the rabbit hole.

In addition, F5 networks is listed as a partner in the Application Delivery category. F5 supports sFlow on their BIG IP platform, see F5 BIG-IP LTM and TMOS 11.4.0, providing visibility into application performance (including response times, URLs, status etc.) and linking the front-end performance seen by clients accessing virtual IP addresses (VIPS) with the performance of individual back-end servers.

Embedding visibility in all the elements of the data center provides comprehensive, cost effective, visibility into data center resources. Visibility is critical in reducing operational complexity, improving performance, decreasing the time to identify the root cause of performance problems, and isolating performance between virtual networks, see Multi-tenant performance isolation.

Monday, July 22, 2013

Top of rack network virtualization


Network virtualization (credit Brad Hedlund)
Support for tunneling protocols (NVGRE, VxLAN etc.) and OpenFlow in top of rack switches allows physical hosts to participate in the virtualized network that connects virtual machines, see Network Virtualization: a next generation modular platform for the data center virtual network. In this architecture, the top of rack switch replicates the functionality of the Open vSwitch (OVS) instances running on the hypervisors, allowing the controllers to flexibly integrate physical and virtual servers within the virtualized network.

Support for sFlow and OpenFlow in the top of rack, virtual switches, and within the network fabric, provides the unified, data center wide, visibility and control needed to optimize virtual machine placement, improve network performance, isolate performance between tenants and defend against DDoS attacks.

Thursday, April 25, 2013

SDN packet broker

Rich Groves described Microsoft's DEMon (Distributed Ethernet Monitoring) network at the recent Open Networking Summit. Rich described the challenges of capturing packets from Microsoft's cloud network, consisting of "thousands and thousands of 10Gig connections." The DEMon capture network was developed because existing solutions were too expensive and didn't scale.

The DEMon capture network makes use of inexpensive merchant silicon based switches as "programmable frame processors." The switches support OpenFlow, allowing an external controller to configure their filtering and forwarding behavior in order to capture and deliver packets to security, compliance, and performance monitoring applications.
Note: Lippis Report 207: The Killer SDN Applications: Network Virtualization and Visualization, describes network visualization as "an SDN killer application" and examines the impact this technology is having on incumbent vendors such as Gigamon, Ixia/Anue, VSS, cPacket, and NetScout.
Rich's talk has already been covered in the news, Microsoft uses OpenFlow SDN for network monitoring and analysis. However, this article focusses on the Proactively Finding Interesting Traffic use case described near the end of the talk that hasn't seen much coverage. The use case is an interesting example of the combined use of OpenFlow and sFlow to dramatically increase to capabilities of the monitoring system.
In the DEMon architecture, a layer of filter switches terminates all the monitor ports. By default the filter switches are configured to drop all packets since the terrabits per second of traffic arriving at the capture network would overwhelm the analysis tools.
Rich commented that, "It just turns out that when you get these merchant silicon switches, you get sFlow for free." Switches supporting the sFlow standard implement packet sampling in silicon, providing scaleable, wire-speed monitoring that can be enabled on all the filter switches. Packet sampling works like a  shrink ray, scaling down the size of the monitoring task so that a single sFlow collector can provide an overview of data center wide traffic.
Rich mentions using the sFlow-RT collector to define interesting flows and thresholds and trigger automatic packet captures using simple Python scripts, yielding "meaningful captures" as part of "a smarter way to find a needle in a haystack."
Finderscope
An analogy for the role that sFlow plays in steering the capture network is that of a finderscope, the small, wide-angle telescope used to provide an overview of the sky and guide the telescope to its target.

How easy is it to build a similar system within your own network? Although not mentioned by name, one can speculate based on the symbol on the slides that the controller is Big Tap from Big Switch Networks. Big Tap provides a high level RESTful API that can be used to direct packet capture. In addition, although the switch vendor wasn't named, there are a number of vendors selling top of rack switches based on the same merchant silicon. Virtually all of these switches support the sFlow standard and many also support OpenFlow, offering a range of choices.

While the DEMon capture network uses a separate filtering layer, the most cost effective solution would be to use the top of rack switches as the filtering layer in the architecture. The simplest solution would be a hybrid OpenFlow deployment in which OpenFlow rules are used to selectively capture specific flows without affecting the normal delivery of the packets.
The diagram shows the elements of a performance aware software defined networking solution like the one described. The combination of sFlow monitoring and SDN controlled packet capture yields significant benefits:
  1. Offload The capture network is a limited resource, both in terms of bandwidth and in the number of flows that can be simultaneously captured.  Offloading as many tasks as possible to the sFlow analyzer frees up resources in the capture network, allowing the resources to be applied where they add most value. A good sFlow analyzer delivers data center wide visibility that can address many traffic accounting, capacity planning and traffic engineering use cases. In addition, many of the packet analysis tools can accept sFlow data directly, for example the Wireshark shown on the DEMon slides, further reducing the cases where a full capture is required.
  2. Context Data center wide monitoring using sFlow provides context for triggering packet capture. For example, sFlow monitoring might show an unusual packet size distribution for traffic to a particular service. Queries to the sFlow analyzer can identify the set of switches and ports involved in providing the service and identify a set of attributes that can be used to selectively capture the traffic (the capture filter needs to be expressed in terms of packet attributes that are understood by the OpenFlow protocol).
  3. DDoS Certain classes of event such as DDoS flood attacks may be too large for the capture network to handle. An sFlow driven SDN controller can be used to mitigate DDoS flood attacks (see DDoS and OpenFlow 1.0 Actual Use-Case: RTBH of DDoS Traffic While Keeping the Target Online), freeing the capture network to focus on identifying more serious application layer attacks, see Gartner Says 25 Percent of Distributed Denial of Services Attacks in 2013 Will Be Application-Based.
To illustrate the benefits of a combined solution, consider the challenge of monitoring tunneled traffic. Tunneled or encapsulated traffic is present in a wide variety of contexts, including: IPv6 migration (Teredo, 6-in-4, 4-in-6 etc.), network virtualization and layer-2 encapsulations (MPLS, Q-in-Q, TRILL, 802.1aq etc.). Capturing tunneled traffic is challenging for an OpenFlow based system since the switch hardware only examines the outer headers and cannot see traffic inside a tunnel. How can captures be triggered based on activity within tunnels?

The following Python script is based on the examples described in performance aware software defined networking and Down the rabbit hole. The script configures sFlow-RT to look for GRE tunnels containing traffic to TCP port 22, generating an alert that can be used to trigger a packet capture:
import requests
import json

groups = {'external':['0.0.0.0/0'],'internal':['10.0.0.0/8']}
flows = {'keys':'ipsource,ipdestination','value':'frames','filter':'stack=eth.ip.gre.ip.tcp&tcpdestinationport=22'}
threshold = {'metric':'watch','value':0}

rt = 'http://localhost:8008'

r = requests.put(rt + '/group/json',data=json.dumps(groups))
r = requests.put(rt + '/flow/watch/json',data=json.dumps(flows))
r = requests.put(rt + '/threshold/watch/json',data=json.dumps(threshold))

eventurl = rt + '/events/json?maxEvents=10&timeout=60'
eventID = -1
while 1 == 1:
  r = requests.get(eventurl + "&eventID=" + str(eventID))
  if r.status_code != 200: break
  events = r.json()
  if len(events) == 0: continue
  eventID = events[0]["eventID"]
  events.reverse()
  for e in events:
    thresholdID = e['thresholdID']
    if "watch" == thresholdID:
      r = requests.get(rt + '/metric/' + e['agent'] + '/' + e['dataSource'] + '.' + e['metric'] + '/json')
      metrics = r.json()
      if len(metrics) > 0:
        evtMetric = metrics[0]
        evtKeys = evtMetric.get('topKeys',None)
        if(evtKeys and len(evtKeys) > 0):
          topKey = evtKeys[0]
          key = topKey.get('key', None)
          value = topKey.get('value',None)
          keys = key.split(",")
          match = [
           {
             "ether-type":"2048",
             "ip-proto":"47",
             "src-ip": str(keys[0]),
             "src-ip-mask":"255.255.255.255",
             "dst-ip": str(keys[1]),
             "dst-ip-mask":"255.255.255.255",
             "src-tp-port":None,
             "dst-tp-port":None,
             "any-traffic":None
           }
          ]
          print match
Running the script generates the following output as soon as a packet is detected:
$ python gre.py 
[{'src-tp-port': None, 'src-ip-mask': '255.255.255.255', 'ip-proto': '47', 'ether-type': '2048', 'any-traffic': None, 'dst-ip': '10.0.0.151', 'dst-ip-mask': '255.255.255.255', 'src-ip': '10.0.0.152', 'dst-tp-port': None}]
In a real deployment, the script would make a REST call to automatically trigger a packet capture, rather than simply printing out details of the tunnel. Triggering packet captures is just one example of an SDN application making use of real-time sFlow analytics, other examples include load balancing large flows and DDoS mitigation.

Saturday, April 20, 2013

Merchant silicon competition

Figure 1: Open Network Platform Switch Reference Design (see Intel Product Brief)
Rose Schooler's keynote at the recent Open Networking Summit described Intel's new reference switch platform. Intel merchant silicon addresses network virtualization and SDN use cases through support for open standards, including: OpenFlow,  NVGRE, VxLAN and sFlow.
Figure 2: Top of rack using Broadcom merchant silicon (from Merchant silicon)
Intel appears to be targeting Broadcom's postion as merchant silicon provider in the data center switch market. Just as competition between Intel, AMD and ARM has spurred innovation, increased choice, and driven down CPU prices, competition between merchant silicon vendors promises similar benefits.

In the compute space, the freedom to choose operating systems (Windows, Linux, Solaris etc.) increases competition among hardware vendors and between operating system vendors. Choices in switch operating system are starting to appear (PicOS and the open source Switch Light project), opening the door to disruptive change in the networking market that is likely to mirror the transition from proprietary minicomputers to commodity x86 servers that occurred in the 1980's.

Monday, October 1, 2012

Link aggregation

Figure 1: Link Aggregation Groups
The title of the recently finalized sFlow LAG Counters Structure specification may not sound like much, but it is an exciting development for managing data center networks. To understand why, it is worth looking at how Link Aggregation Groups (LAGs) are deployed.

Note: There is much confusion caused by the many different names that can be used to describe link aggregation, including Port Grouping, Port Trunking, Link Bundling, NIC/Link Bonding, NIC/Link Teaming etc. These are all examples of link aggregation and the discussion in this paper is applicable.

Figure 1 shows a number of common uses for link aggregation. Switches A, B, C and D are interconnected by LAGs, each of which is made up of four individual links. In this case the LAGs are used to provide greater bandwidth between switches at the network core.

A LAG generally doesn't provide the same performance characteristics as a single link with equivalent capacity. In this example, suppose that the LAGs are 4 x 10 Gigabit Ethernet. The LAG needs to ensure in-order delivery of packets since many network protocols perform badly when packets arrive out of order (e.g. TCP). Packet header fields are examined and used to assign all packets that are part of a connection to the same link within the aggregation group. The result is that the maximum bandwidth available to any single connection is 10 Gigabits per second, not 40 Gigabits per second. The LAG can carry 40 Gigabits per second, but the traffic must be a mixture of connections.

The alternative of a single 40G Ethernet link allows a single connection to use the full bandwidth of the link and transfer data at 40 Gigabits per second. However, the LAG is potentially more resilient, since a link failure will simply reduce the LAG capacity by 25% and the two switches will still have connectivity. On the other hand the LAG involves four times as many links and so there is an increased likelihood of link failures.

Servers are often connected to two separate switches to ensure that if one switch fails, the server has backup connectivity through the second switch. In this example, servers A and B are connected to switches C and D. A limitation of this approach is that the backup link is idle and the bandwidth isn't available to the server.

A Multi-chassis Link Aggregation Group (MLAG) allows the server to actively use both links, treating them as a single, high capacity LAG. The "multi-chassis" part of the name refers to what happens at the other end of the link. The two switches C and D communicate with each other in order to handle the two links as if they were arriving at a single switch as part of a conventional LAG, ensuring in-order delivery of packets etc.

There is no standard for logically combining the switches to support MLAGs - each vendor has their own approach (e.g. Hewlett-Packard Intelligent Redundant Framework (IRF), Cisco Virtual Switching System (VSS), Cisco Virtual PortChannel (vPC), Arista MLAG domains, Dell/Force10 VirtualScale (VS) etc.). However, as far as the servers are concerned the network adapters are combined (or bonded) to form a simple LAG that provides the benefit of increased bandwidth and redundancy. However, a potential drawback of actively using both adapters is an increased vulnerability to failures, since bandwidth will drop by 50% during a failure, potentially triggering congestion related service problems.

MLAGs aren't restricted to the server access layer. Looking at Figure 1, if switches A and B share control information and switches C and D share control information, it is possible to aggregate links into two groups of 8, or even a single group of 16. One of the benefits of aggregating core links is that the topology can become logically "loop free", ensuring fast convergence in the event of a link failure and relegating spanning tree to provide protection against configuration errors.

Based on the discussion, it should be clear that managing the performance of LAGs requires visibility into network traffic patterns and paths through the LAGs and member links, visibility into link utilizations and the balance between group members, and visibility into the health of each link.

The LAG extension to the sFlow standard builds the detailed visibility that sFlow already provides into switched network traffic to provide additional detail about LAG topology and health. The IEEE 802.3 LAG MIB defines the set of objects describing elements of the LAG and counters than can be used to monitor LAG health. The sFlow LAG extension simply maps values defined in the MIB into an sFlow counter structure that is exported using sFlow's scaleable "push" mechanism, allowing large scale monitoring of LAG based network architectures.

The new measurements are best understood by examining a single aggregation group.
Figure 2: Detail of a Link Aggregation Group
Figure 2 provides a detailed view of the LAG connecting switches A and C. Ethernet cables connect ports 2, 4, 6 and 8 on Switch A to ports 1, 3, 5 and 7 respectively on Switch C. The two switches communicate with each other using the Link Aggregation Control Protocol (LACP) in order to check the health of each link and negotiate settings to establish and maintain the LAG.

LACP associates a System ID with each switch. The system ID is simply a vendor assigned MAC address that is unique to each switch. In this example, Switch A has the System ID 000000000010 and Switch B has the ID 000000000012.

Each switch assigns an Aggregation ID, or logical port number, to the group of physical ports. Switch A identifies the LAG as port 501 and Switch C identifies the LAG as port 512.

The following sflowtool output shows what an interface counter sample exported by Switch A reporting on physical port 2, would look like:
startSample ----------------------
sampleType_tag 0:2
sampleType COUNTERSSAMPLE
sampleSequenceNo 110521
sourceId 0:2
counterBlock_tag 0:1
ifIndex 2
networkType 6
ifSpeed 100000000
ifDirection 1
ifStatus 3
ifInOctets 35293750622
ifInUcastPkts 241166136
ifInMulticastPkts 831459
ifInBroadcastPkts 11589475
ifInDiscards 0
ifInErrors 0
ifInUnknownProtos 0
ifOutOctets 184200359626
ifOutUcastPkts 375811771
ifOutMulticastPkts 1991731
ifOutBroadcastPkts 5001804
ifOutDiscards 63606
ifOutErrors 0
ifPromiscuousMode 1
counterBlock_tag 0:2
dot3StatsAlignmentErrors 1
dot3StatsFCSErrors 0
dot3StatsSingleCollisionFrames 0
dot3StatsMultipleCollisionFrames 0
dot3StatsSQETestErrors 0
dot3StatsDeferredTransmissions 0
dot3StatsLateCollisions 0
dot3StatsExcessiveCollisions 0
dot3StatsInternalMacTransmitErrors 0
dot3StatsCarrierSenseErrors 0
dot3StatsFrameTooLongs 0
dot3StatsInternalMacReceiveErrors 0
dot3StatsSymbolErrors 0
counterBlock_tag 0:7
actorSystemID 000000000010
partnerSystemID 000000000012
attachedAggID 501
actorAdminPortState 5
actorOperPortState 61
partnerAdminPortState 5
partnerOperPortState 61
LACPDUsRx 11
markerPDUsRx 0
markerResponsePDUsRx 0
unknownRx 0
illegalRx 0
LACPDUsTx 19
markerPDUsTx 0
markerResponsePDUsTx 0
endSample   ----------------------
The LAG MIB should be consulted for detailed descriptions of the fields, for example, refer to the following LacpState definition from the MIB to understand the operational port state values:
LacpState ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        “The Actor and Partner State values from the LACPDU.”
    SYNTAX      BITS {
  lacpActivity(0),
  lacpTimeout(1),
  aggregation(2),
  synchronization(3),
  collecting(4),
  distributing(5),
  defaulted(6),
  expired(7)
                }
In the sflowtool output the actor (local) and partner (remote) operational state associated with the LAG member is 61, which is 111101 in binary. This value indicates that the lacpActivity(0), aggregation(2), synchronization(3), collecting(4) and distributing(5) bits are set - i.e. the link is healthy.

While this article discussed the low level details of LAG monitoring, performance management tools should automate this analysis and allow the health and performance of all the LAGs to be tracked. In addition, sFlow integrates LAG monitoring with measurements of traffic flows, server activity and application response times to provide comprehensive visibility into data center performance. The Data center convergence, visibility and control presentation describes the critical role that measurement plays in managing costs and optimizing performance.

Today, almost every switch vendor offers products that implement the sFlow standard. If you make use of link aggregation, ask your switch vendor add support for the LAG extension. Implementing the sFlow LAG extension is straightforward if they already support IEEE LAG MIB.