Thursday, October 30, 2025

Vector Packet Processor (VPP) dropped packet notifications


Vector Packet Processor (VPP) release 25.10 extends the sFlow implementation to include support for dropped packet notifications, providing detailed, low overhead, visibility into traffic flowing through a VPP router, see Vector Packet Processor (VPP) for performance information.
sflow sampling-rate 10000
sflow polling-interval 20
sflow header-bytes 128
sflow direction both
sflow drop-monitoring enable
sflow enable GigabitEthernet0/8/0
sflow enable GigabitEthernet0/9/0
sflow enable GigabitEthernet0/a/0
The above VPP configuration commands enable sFlow monitoring of the VPP dataplane, randomly sampling packets, periodically polling counters, and capturing dropped packets and reason codes. The measurements are send via Linux netlink messages to an instance of the open source Host sFlow agent (hsflowd) which combines the measurements and streams standard sFlow telemetry to a remote collector.
sflow {
  collector { ip=192.0.2.1 udpport=6343 }
  psample { group=1 egress=on }
  dropmon { start=on limit=50 }
  vpp { }
}
The /etc/hsflowd.conf file above enables the modules needed to receive netlink messages from VPP and send the resulting sFlow telemetry to a collector at 192.0.2.1. See vpp-sflow for detailed instructions.
docker run -p 6343:6343/udp sflow/sflowtool
Run sflowtool on the sFlow collector host to verify verify that the data is being received and to see the information available in the sFlow telemetry stream. The pre-built sflow/sflowtool Docker image is the fastest way to run sflowtool.
Docker also makes it easy to try out other sFlow analytics tools, for example, Deploy real-time network dashboards using Docker compose, describes how to quickly set up measurement stack consisting of the sFlow-RT real-time analytics engine, Prometheus time series database, and Grafana dashboard builder.

The sFlow VPP module delivers the same industry standard network performance monitoring available in switches and routers from leading vendors, including Arista, Cisco, Dell, Juniper, NVIDIA, VyOS, etc. to provide comprehensive, network-wide, visibility.

Monday, July 28, 2025

Linux packet sampling using eBPF

Linux 6.11+ kernels provide TCX attachment points for eBPF programs to efficiently examine packets as they ingress and egress the host. The latest version of the open source Host sFlow agent includes support for TCX packet sampling to stream industry standard sFlow telemetry to a central collector for network wide visibility, e.g. Deploy real-time network dashboards using Docker compose describes how to quickly set up a Prometheus database and use Grafana to build network dashboards.

static __always_inline void sample_packet(struct __sk_buff *skb, __u8 direction) {
    __u32 key = skb->ifindex;
    __u32 *rate = bpf_map_lookup_elem(&sampling, &key);
    if (!rate || (*rate > 0 && bpf_get_prandom_u32() % *rate != 0))
        return;

    struct packet_event_t pkt = {};
    pkt.timestamp = bpf_ktime_get_ns();
    pkt.ifindex = skb->ifindex;
    pkt.sampling_rate = *rate;
    pkt.ingress_ifindex = skb->ingress_ifindex;
    pkt.routed_ifindex = direction ? 0 : get_route(skb);
    pkt.pkt_len = skb->len;
    pkt.direction = direction;

    __u32 hdr_len = skb->len < MAX_PKT_HDR_LEN ? skb->len : MAX_PKT_HDR_LEN;
    if (hdr_len > 0 && bpf_skb_load_bytes(skb, 0, pkt.hdr, hdr_len) < 0)
        return;
    bpf_perf_event_output(skb, &events, BPF_F_CURRENT_CPU, &pkt, sizeof(pkt));
}

SEC("tcx/ingress")
int tcx_ingress(struct __sk_buff *skb) {
    sample_packet(skb, 0);

    return TCX_NEXT;
}

SEC("tcx/egress")
int tcx_egress(struct __sk_buff *skb) {
    sample_packet(skb, 1);

    return TCX_NEXT;
}

The sample.bpf.c file is compiled into eBPF code that the Host sFlow mod_epcap.c module uses to tap packets on selected interfaces. The highlighted code uses the bpf_get_random_u32() function to randomly select packets using the configured sampling rate for the interface. Once a packet is selected to be sampled, the packet header and selected metadata is captured and sent to the Host sFlow agent as a performance event via the bpf_perf_event_output() call. The ability to perform the sampling action in the kernel dramatically reduces the overhead associated with network traffic monitoring, since only the small fraction of sampled packets need to be transferred to the user space Host sFlow agent.

static __always_inline __u32 get_route(struct __sk_buff *skb) {
    __u32 key = 0;
    __u32 *routing_enabled = bpf_map_lookup_elem(&routing, &key);
    if(!routing_enabled || !*routing_enabled)
	return 0;

    if(skb->pkt_type != PACKET_HOST)
	return 0;

    void *data = (void *)(long)skb->data;
    void *data_end = (void *)(long)skb->data_end;
    struct ethhdr *eth = data;
    if ((void *)(eth + 1) > data_end)
        return 0;
    __u32 proto = bpf_ntohs(eth->h_proto);
    if(proto == ETH_P_IP) {
        struct iphdr *ip = data + sizeof(*eth);
        if ((void *)(ip + 1) > data_end)
            return 0;
        struct bpf_fib_lookup fib = {0};
        fib.family      = AF_INET;
        fib.ipv4_src    = ip->saddr;
        fib.ipv4_dst    = ip->daddr;
        fib.tos         = ip->tos;
	fib.l4_protocol = ip->protocol;
	fib.sport       = 0;
	fib.dport       = 0;
	fib.tot_len     = bpf_ntohs(ip->tot_len);
        fib.ifindex     = skb->ifindex;
        long rc = bpf_fib_lookup(skb, &fib, sizeof(fib), 0);
        if(rc != BPF_FIB_LKUP_RET_SUCCESS)
	   return 0;
        return fib.ifindex;
    } else if(proto == ETH_P_IPV6) {
	struct ipv6hdr *ipv6 = data + sizeof(*eth);
        if ((void *)(ipv6 + 1) > data_end)
	    return 0;
        struct bpf_fib_lookup fib = {0};
        fib.family      = AF_INET6;
	__builtin_memcpy(fib.ipv6_src, &ipv6->saddr, sizeof(ipv6->saddr));
        __builtin_memcpy(fib.ipv6_dst, &ipv6->daddr, sizeof(ipv6->daddr));
	fib.flowinfo    = *(__be32 *) ipv6 & bpf_htonl(0x0FFFFFFF);
	fib.l4_protocol = ipv6->nexthdr;
	fib.sport       = 0;
	fib.dport       = 0;
	fib.tot_len     = bpf_ntohs(ipv6->payload_len);
        fib.ifindex     = skb->ifindex;
        long rc = bpf_fib_lookup(skb, &fib, sizeof(fib), 0);
        if(rc != BPF_FIB_LKUP_RET_SUCCESS)
           return 0;
        return fib.ifindex;	
    }
    return 0;
}

If the Linux host has been configured as a router, then the bpf_fib_lookup() is used to to determine the forwarding decision (egress port) for sampled ingress packets.

Note: The mod_pcap.c module works on older Linux kernels and uses traditional BPF to perform random packet sampling. The main advantage of the mod_epcap module is its ability add additional metadata to each sampled packet.

Monday, October 7, 2024

Vector Packet Processor (VPP)

VPP with sFlow - Part 1 and VPP with sFlow - Part 2 describe the journey to add industry standard sFlow instrumentation to the Vector Packet Processor (VPP) an Open Source Terabit Software Dataplane for software routers running on commodity x86 / ARM hardware.

The main conclusions based on testing described in the two VPP blog posts are:

  1. If sFlow is not enabled on a given interface, there is no regression on other interfaces.
  2. If sFlow is enabled, copying packets costs 11 CPU cycles on average
  3. If sFlow takes a sample, it takes only marginally more CPU time to enqueue.
    • No sampling gets 9.88Mpps of IPv4 and 14.3Mpps of L2XC throughput,
    • 1:1000 sampling reduces to 9.77Mpps of L3 and 14.05Mpps of L2XC throughput,
    • and an overly harsh 1:100 reduces to 9.69Mpps and 13.97Mpps only.

The VPP sFlow plugin provides a lightweight method of exporting real-time sFlow telemetry from a VPP based router. Including the plugin with VPP distributions has no impact on performance. Enabling the plugin provides real-time visibility that opens up additional use cases for VPPs programmable dataplane. For example, VPP is well suited to packet filtering use cases where the number of ACL entries would exceed the capabilities of an ASIC. Combined with real-time visibility to identify DDoS attacks, VPP provides an effective means of mitigating the attacks by scrubbing the unwanted traffic.

Thursday, February 22, 2024

VyOS 1.4 LTS released

Protectli Vault - 4 Port

The VyOS 1.4.0 (Sagitta) LTS release announcement is exciting news! VyOS is an open source router operating system based on Linux that can be installed on commodity PC hardware - for optimal performance at least 1GB RAM and 4GB of storage space is recommended.

The new 1.4 LTS release includes a significantly enhanced implementation of industry standard sFlow telemetry based on the open source Host sFlow agent.

set system sflow interface eth0
set system sflow interface eth1
set system sflow interface eth2
set system sflow interface eth3
set system sflow polling 30
set system sflow sampling-rate 1000
set system sflow drop-monitor-limit 50
set system sflow server 192.0.2.100
Enter the commands above to enable sFlow monitoring on interfaces eth0, eth1, eth2, and eth3. Interface counters will be exported every 30 seconds, packets will be sampled with probability 1/1000, and up to 50 packet headers (and drop reasons) per second will collected from packets dropped by the router. The sFlow telemetry stream will be sent to an sFlow collector at 192.0.2.100.

Running Docker on the sFlow collector makes it easy to run a variety of sFlow analytics tools.

docker run --rm -p 6343:6343/udp sflow/sflowtool
Run the sflow/sflowtool image to decode and print the contents of the sFlow telemetry stream and verify receipt of data.
docker run --rm -p 6343:6343/udp sflow/tcpdump tcp port 80
Run the sflow/tcpdump image to decode and filter sampled packet headers. For more complex packet analysis tasks, try the sflow/tshark image.
Run the sflow/sflowtrend image to trend interface counters and top flows.
Deploy real-time network dashboards using Docker compose describes how to configure Prometheus and Grafana to capture time series data and create custom dashboards.
Dropped packet reason codes in VyOS describes how the new Linux kernel in VyOS 1.4 provides detailed visibility into every dropped packet (including the reason it was dropped). This cabability is used by the new sFlow agent implement the sFlow Dropped Packet Notification Structures extension to provide network-wide visibility into dropped packets.

Download VyOS today to try out the new features. Pre-built LTS images are available with paid support, but anyone can build an image from sources or download the latest rolling release.

Monday, January 15, 2024

Raspberry Pi 5 network emulation with Containerlab

The GitHub sflow-rt/containerlab project contains example network topologies for the Containerlab network emulation tool that demonstrate real-time streaming telemetry in realistic data center topologies and network configurations. The examples use the same FRRouting (FRR) engine that is part of SONiC, NVIDIA Cumulus Linux, and DENT network operating systems. Containerlab can be used to experiment before deploying solutions into production. Examples include: tracing ECMP flows in leaf and spine topologies, EVPN visibility, and automated DDoS mitigation using BGP Flowspec and RTBH controls.
Raspberry Pi 5 real-time network analytics describes how to install Docker on a Raspberry Pi 5.
docker run hello-world
Run the hello-world container to verify that Docker in properly installed and running before proceeding.
git clone https://github.com/sflow-rt/containerlab.git
Download the sflow-rt/containerlab project from GitHub.
cd containerlab
./run-clab
Start Containerlab.
containerlab deploy -t clos5.yml
Start the 5 stage leaf and spine topology shown at the top of this page. The initial launch may take a couple of minutes as the container images are downloaded for the first time. Once the images are downloaded, the topology deploys in around 10 seconds.
./topo.py clab-clos5
Push the topology to the sFlow-RT analytics software.
An instance of the sFlow-RT real-time analytics engine receives industry standard sFlow telemetry from all the switches in the network. All of the switches in the topology are configured to send sFlow to the sFlow-RT instance. In this case, Containerlab is running the pre-built sflow/clab-sflow-rt image which packages sFlow-RT with useful applications for exploring the data.
Connect to the web interface on port 8008. The sFlow-RT dashboard verifies that telemetry is being received from 10 agents (the 10 switches in the Clos fabric). See the sFlow-RT Quickstart guide for more information.
The Containerlab Dashboard (click on sFlow-RT Apps tab and containerlab-dashboard button) shows real-time dashboard displaying up to the second traffic.
docker exec -it clab-clos5-h1 iperf3 -c 172.16.4.2
Each of the hosts in the network has an iperf3 server, so running the above command will test bandwidth between h1 and h4.
docker exec -it clab-clos5-h1 iperf3 -c 2001:172:16:4::2
Generate a large IPv6 flow between h1 and h4. The traffic flows should immediately appear in the Top Flows chart. You can check the accuracy by comparing the values reported by iperf3 with those shown in the chart.
Click on the Topology tab to see a real-time weathermap of traffic flowing over the topology. See how repeated iperf3 tests take different ECMP (equal-cost multi-path) routes across the network.
docker exec -it clab-clos5-leaf1 vtysh
Linux with open source routing software (FRRouting) is an accessible alternative to vendor routing stacks (no registration / license required, no restriction on copying means you can share images on Docker Hub, no need for virtual machines). FRRouting is popular in production network operating systems (e.g. Cumulus Linux, SONiC, DENT, etc.) and the VTY shell provides an industry standard CLI for configuration, so labs built around FRR allow realistic network configurations to be explored.
docker exec -it clab-clos5-leaf1 vtysh -c "show running-config"
Use vtysh to show the running configuration on leaf1.
containerlab destroy -t clos5.yml
When you are finished, run the above command to stop the containers and free the resources associated with the emulation. Try out other topologies from the project to explore topics such as DDoS mitigation, BGP Flowspec, and EVPN.

Note: If you are building your own topologies, the Raspberry Pi 5 8G can comfortably handle topologies with up to 50 FRR/Alpine Linux nodes.

Getting Started provides an introduction to sFlow-RT analytics and APIs. Containerlab provides a useful environment for developing and testing monitoring applications for sFlow-RT before moving them into production.

Moving monitoring solutions from Containerlab to production is straightforward since sFlow is widely implemented in datacenter equipment from vendors including: A10, Arista, Aruba, Cisco, Edge-Core, Extreme, Huawei, Juniper, NEC, Netgear, Nokia, NVIDIA, Quanta, and ZTE. In addition, the open source Host sFlow agent makes it easy to extend visibility beyond the physical network into the compute infrastructure.

Raspberry Pi 5 real-time network analytics describes how to deploy an sFlow-RT, Prometheus, and Grafana monitoring stack to monitor live network traffic.

Friday, November 17, 2023

SC23 Over 6 Terabits per Second of WAN Traffic

The world’s fastest temporary internet service gets turned on in Denver for one week only describes the SCinet temporary network built to support the The International Conference for High Performance Computing, Networking, Storage, and Analysis (SC23) this week in Denver. The SC23 WAN Stress Test chart demonstrates that the provisioned 6.71 terabits bits per second capacity was pushed to the limits.
SC23 SCinet traffic describes the architecture of the real-time monitoring system used to comprehensively monitor the SCinet network and generate these charts. This chart shows that over 175 Petabytes of data were transfered during the show.
SC23 Dropped packet visibility demonstration describes a joint demonstration by InMon Corp and Arista Networks of one of newest developments in sFlow telemetry, identifying every dropped packet, the reason it was dropped, and the location it was dropped across all the switches in real-time.
SC23 WiFi Traffic Heatmap shows a real-time view of WiFi usage at the conference displayed on a conference floorplan.
Finally, SC23 Data Transfer Node TCP Metrics demonstrates how standard metrics maintained by the Linux kernel can be used to augment sFlow telemetry and track the performance of large science data transfers.

Thursday, November 16, 2023

SC23 Data Transfer Node TCP Metrics

The dashboard shown above is based on the open source sflow-rt/dtn project. The dashboard shows data captured from The International Conference for High Performance Computing, Networking, Storage, and Analysis (SC23) being held this week in Denver.

The dashboard displays data gathered from open source Host sFlow agents installed on Data Transfer Nodes (DTNs) run by the Caltech High Energy Physics Department and used for handling transfer of large scientific data sets (for example, accessing experiment data from the CERN particle accelerator). Network performance monitoring describes how the Host sFlow agents augment standard sFlow telemetry with measurements that the Linux kernel maintains as part of the normal operation of the TCP protocol stack.

The dashboard shows 5 large flows (greater than 50 Gigabits per Second). For each large flow being tracked, additional TCP performance metrics are displayed:

  • RTT The round trip time observed between DTNs
  • RTT Wait The amount of time that data waits on sender before it can be sent.
  • RTT Sdev The standard deviation on observed RTT. This variation is a measure of jitter.
  • Avg. Packet Size The average packet size used to send data.
  • Packets in Flight The number of unacknowledged packets.

See Defining Flows for full range of attributes that can be used to create flow metrics.

The conference network used in the demonstration, SCinet, is described as the most powerful and advanced network on Earth, connecting the SC community to the world.
In this example, the sFlow-RT real-time analytics engine receives sFlow telemetry from switches, routers, and servers in the SCinet network and creates metrics to drive the real-time charts in the dashboard. Getting Started provides a quick introduction to deploying and using sFlow-RT for real-time network-wide flow analytics.

Finally, check out the SC23 Dropped packet visibility demonstration, SC23 SCinet traffic, and SC23 WiFi Traffic Heatmap for additional network visibility demonstrations from the show.

Tuesday, May 23, 2023

Leaf and spine network emulation on Mac OS M1/M2 systems


The GitHub sflow-rt/containerlab project contains example network topologies for the Containerlab network emulation tool that demonstrate real-time streaming telemetry in realistic data center topologies and network configurations. The examples use the same FRRouting (FRR) engine that is part of SONiC, NVIDIA Cumulus Linux, and DENT network operating systems. Containerlab can be used to experiment before deploying solutions into production. Examples include: tracing ECMP flows in leaf and spine topologies, EVPN visibility, and automated DDoS mitigation using BGP Flowspec and RTBH controls.

The Containerlab project currently has limited support for Mac OS, stating "ARM-based Macs (M1/2) are not supported, and no binaries are generated for this platform. This is mainly due to the lack of network images built for arm64 architecture as of now." However, this argument doesn't apply to the Linux based images used in these examples.

First install Docker Desktop on your Apple silicon based Mac (select the Apple Chip option).

mkdir clab
cd clab
docker run --rm -it --privileged \
  --network host --pid="host" \
  -v /var/run/docker.sock:/var/run/docker.sock \
  -v /run/netns:/run/netns \
  -v $(pwd):$(pwd) -w $(pwd) \
  sflow/clab bash

Run Containerlab by typing the above commands in a terminal. This command uses a pre-built multi-architecture sflow/clab image. If you are running on an x86 platform, follow the official Containerlab Installation instructions.

git clone https://github.com/sflow-rt/containerlab.git

Download the Containerlab topologies from the sflow-rt/containerlab project.

containerlab deploy -t containerlab/clos5.yml

Start the 5 stage leaf and spine topology shown at the top of this page. The initial launch may take a couple of minutes as the container images are downloaded for the first time. Once the images are downloaded, the topology deploys in around 10 seconds.

An instance of the sFlow-RT real-time analytics engine receives industry standard sFlow telemetry from all the switches in the network. All of the switches in the topology are configured to send sFlow to the sFlow-RT instance. In this case, Containerlab is running the pre-built sflow/prometheus image which packages sFlow-RT with useful applications for exploring the data.

Connect to the web interface, http://localhost:8008. The sFlow-RT dashboard verifies that telemetry is being received from 10 agents (the 10 switches in the Clos fabric). See the sFlow-RT Quickstart guide for more information.

The screen capture shows a real-time view of traffic flowing across the network during a series iperf3 tests. Click on the sFlow-RT Apps menu and select the browse-flows application, or click here for a direct link to a chart with the settings shown above.
docker exec -it clab-clos5-h1 iperf3 -c 172.16.4.2

Each of the hosts in the network has an iperf3 server, so running the above command will test bandwidth between h1 and h4.

docker exec -it clab-clos5-leaf1 vtysh

Linux with open source routing software (FRRouting) is an accessible alternative to vendor routing stacks (no registration / license required, no restriction on copying means you can share images on Docker Hub, no need for virtual machines). FRRouting is popular in production network operating systems (e.g. Cumulus Linux, SONiC, DENT, etc.) and the VTY shell provides an industry standard CLI for configuration, so labs built around FRR allow realistic network configurations to be explored.

containerlab destroy -t containerlab/clos5.yml

When you are finished, run the above command to stop the containers and free the resources associated with the emulation. Try out other topologies from the project to explore topics such as DDoS mitigation, BGP Flowspec, and EVPN.

Moving the monitoring solution from Containerlab to production is straightforward since sFlow is widely implemented in datacenter equipment from vendors including: A10, Arista, Aruba, Cisco, Edge-Core, Extreme, Huawei, Juniper, NEC, Netgear, Nokia, NVIDIA, Quanta, and ZTE. In addition, the open source Host sFlow agent makes it easy to extend visibility beyond the physical network into the compute infrastructure.

Monday, April 3, 2023

Dropped packet reason codes in VyOS

The article VyOS with Host sFlow agent describes how to use industry standard sFlow telemetry to monitor network traffic flows and statistics in the latest VyOS rolling releases. VyOS dropped packet notifications describes how sFlow also provides visibility into network packet drops and Dropped packet reason codes in Linux 6+ kernels describes how newer kernels are able to provide specific reasons for dropping packets. 
vyos@vyos:~$ uname -r
6.1.22-amd64-vyos

The latest VyOS rolling release runs on a Linux 6.1 kernel and the latest release of VyOS now provides enhanced visibility into dropped packets using kernel reason codes.

vyos@vyos:~$ show version
Version:          VyOS 1.4-rolling-202303310716
Release train:    current

Built by:         autobuild@vyos.net
Built on:         Fri 31 Mar 2023 07:16 UTC
Build UUID:       1a7448d9-d53c-48a0-8644-ed1970c1abb8
Build commit ID:  75c9311fba375e

Architecture:     x86_64
Boot via:         installed image
System type:       guest

Hardware vendor:  innotek GmbH
Hardware model:   VirtualBox
Hardware S/N:     0
Hardware UUID:    da75808d-ff60-1d4c-babd-84a7fa341053

Copyright:        VyOS maintainers and contributors
Verify that the version of of VyOS is VyOS 1.4-rolling-202303310716 or later.

In the previous article, VyOS dropped packet notifications,  two tests were performed, the first a failed attempt to connect to the VyOS router using telnet (telnet has been disabled in the router config), and the second a traceroute test between two hosts connected to the router. The sFlow drop reason codes reported for these two tests were unknown_l4 and unknown_l3 respectively. The Linux kernel functional names weren't much more specific, tcp_v4_rcv and ip_forward respectively. However, in this case, the Linux 6.1 kernel instrumentation allows more specific sFlow drop reasons to be reported, as shown in the chart at the top of this article.

  • port_unreachable This sFlow drop reason code is defined by reference to RFC 1812 section 5.2.7.1 and is defined as "Port Unreachable - generated if the designated transport protocol (e.g., UDP) is unable to demultiplex the datagram in the transport layer of the final destination but has no protocol mechanism to inform the sender"
  • ip_1_parsing This sFlow drop reason code is defined by reference to Devlink Trap and is defined as "Traps packets dropped due to an error in the first IP header parsing. This packet trap could include packets which do not pass an IP checksum check, a header length check (a minimum of 20 bytes), which might suffer from packet truncation thus the total length field exceeds the received packet length etc."
The detailed reasons make it easier to identify the root causes of packet drops, particularly when combined with information from the dropped packet's header that is also included in the sFlow Dropped Packet Notification messages.

Thursday, March 30, 2023

Dropped packet reason codes in Linux 6+ kernels

Using sFlow to monitor dropped packets describes support for standard sFlow Dropped Packet Notications in the open source Host sFlow agent. This article describes additional capabilities in Linux 6+ kernels that clarify reasons why packets are dropped in the kernel.

The recent addition of dropreason.h in Linux 6+ kernels provides detailed reasons for packet drops. The netlink drop_monitor API has been extended to include the NET_DM_ATTR_REASON attribute to report the drop reason, see net_dropmon.h.

The following example illustrates the value of the reason code in explaining Linux packet drops.

tcp_v4_rcv+0x7c/0xef0
The value of NET_DM_ATTR_SYMBOL shown above indicates that the packet was dropped in the tcp_v4_rcv function in Linux kernel at memory location 0x7c/0xef0. While this information is helpful, there are many reasons why a TCP packet may be dropped.
NO_SOCKET
In this case, the value of NET_DM_ATTR_REASON shown above indicates that the TCP packet was dropped because no application had opened a socket and so there was nowhere to deliver the packet.

In the case of Linux-based hardware switches or smart network adapters, where packet processing is offloaded to hardware, the netlink drop_monitor events include NET_DM_ATTR_HW_TRAP_GROUP_NAME and NET_DM_ATTR_HW_TRAP_NAME attributes and packet header information supplied by the hardware driver, see Devlink Trap.

The latest version of the open source Host sFlow agent includes adds support for the NET_DM_ATTR_REASON attribute to improve the accuracy of the sFlow drop_reason.

port_unreachable
In our example, the Host sFlow is now able to report port_unreachable as the reason for the dropped packet, rather than a generic unknown_l4 reason reported for older kernels.

The screen capture at the top of this article shows dropped packet information displayed in real-time using the Discard Browser application running on the sFlow-RT analytics engine. The chart demonstrates how the combination of information from the header of the dropped packet along with the reason for dropping the packet quickly gets to the root cause of the packet drop. In this case an attempt has been made from 172.16.1.174 to connect to 172.16.1.1 via telnet (tcp port 23) and telnet has not been enabled on the server so the packet was dropped - as it should be since telnet is not a secure method of connecting.

docker run --name sflow-rt -p 8008:8008 -p 6343:6343/udp -d sflow/prometheus

A quick way to experiment with sFlow is to run the pre-built sflow/prometheus image using Docker. The bundled Discard Browser with the settings shown in the screen capture can be launched by clicking here.

Monday, March 27, 2023

VyOS dropped packet notifications

VyOS with Host sFlow agent describes how to configure and analyze industry standard sFlow telemetry recently added to the VyOS open source router platform. This article discusses sFlow dropped packet notifications support added to the latest release.

Dropped packets have a profound impact on network performance and availability. Packet discards due to congestion can significantly impact application performance. Dropped packets due to black hole routes, expired TTLs, MTU mismatches, etc. can result in insidious connection failures that are time consuming and difficult to diagnose. Visibility into dropped packets offers significant benefits for network troubleshooting, providing real-time network-wide visibility into the specific packets that were dropped as well the reason the packet was dropped. This visibility instantly reveals the root cause of drops and the impacted connections.

vyos@vyos:~$ show version
Version:          VyOS 1.4-rolling-202303260914
Release train:    current

Built by:         autobuild@vyos.net
Built on:         Sun 26 Mar 2023 09:14 UTC
Build UUID:       72b34f74-bfcd-4b51-9b95-544319c2dac5
Build commit ID:  d68bda6a295ba9

Architecture:     x86_64
Boot via:         installed image
System type:       guest

Hardware vendor:  innotek GmbH
Hardware model:   VirtualBox
Hardware S/N:     0
Hardware UUID:    df0a2b79-b8c4-8342-a27f-76aa3e52ad6d

Copyright:        VyOS maintainers and contributors

Verify that the version of of VyOS is VyOS 1.4-rolling-202303260914 or later.

On VyOS dropped packet monitoring relies on instrumentation built into recent Linux kernels and exposed through the netlink drop_monitor API. Enabling drop_monitor in VyOS kernel configuration allows the Host sFlow agent to capture and export information on dropped packets.
set system sflow interface eth0
set system sflow interface eth1
set system sflow interface eth2
set system sflow polling 30
set system sflow sampling-rate 1000
set system sflow drop-monitor-limit 50
set system sflow server 10.0.0.30 port 6343
The drop-monitor-limit configuration entry enables dropped packet monitoring and sets a rate limit of 50 dropped packets notifications per second.
docker run --name sflow-rt -p 8008:8008 -p 6343:6343/udp -d sflow/prometheus

A quick way to experiment with sFlow is to run the pre-built sflow/prometheus image using Docker on the sFlow server (in this case on 10.0.0.30). The chart at the top of the page uses the Discard Browser application to display an up to the second view of packets dropped by the VyOS router, click on this link to open the application with the settings shown.

The chart shows the results of two tests, the first a failed attempt to connect to the VyOS router using telnet (telnet has been disabled in the router config), and the second a traceroute test between two hosts connected to the router. The reason field reports the sFlow drop reason code and the function reports the linux kernel function that dropped the packet. With the telnet test, the packet was dropped in the tcp_v4_rcv function and is reported as an unknown_l4 sFlow reason. In the case of the traceroute test, 3 packets were dropped in the ip_forward function and are reported as unknown_l3 reason.

Enabling sFlow dropped packet notifications on all switches, routers, and hosts provides end-to-end visibility into dropped packets, rapidly identifying the location and reason for packet drops as well as identifying the impacted services.

Dropped packet monitoring complements sFlow's existing counter polling and packet sampling mechanisms and shares a common data model so that all three sources of data can be correlated. For example, if packets are being discarded because of buffer exhaustion, the discard records don't necessarily tell the whole story. The discarded packets may represent mice flows that are victims of an elephant flow. Packet samples will reveal the traffic that isn't being dropped and provide a more complete picture. Counter data adds additional information such as CPU load, interface speed, link utilization, packet and discard rates that further completes the picture.

Friday, March 17, 2023

VyOS with Host sFlow agent

VyOS described deficiencies with the embedded sFlow implementation in the open source VyOS router operating system and suggested that the open source Host sFlow agent be installed as an alternative. The VyOS developer community embraced the suggestion and has been incredibly responsive,  integrating, and releasing a version of VyOS with Host sFlow support within a week.
vyos@vyos:~$ show version
Version:          VyOS 1.4-rolling-202303170317
Release train:    current

Built by:         autobuild@vyos.net
Built on:         Fri 17 Mar 2023 03:17 UTC
Build UUID:       45391302-1240-4cc7-95a8-da8ee6390765
Build commit ID:  e887f582cfd7de

Architecture:     x86_64
Boot via:         installed image
System type:       guest

Hardware vendor:  innotek GmbH
Hardware model:   VirtualBox
Hardware S/N:     0
Hardware UUID:    871dd0f0-c4ec-f147-b1a7-ed536511f141

Copyright:        VyOS maintainers and contributors
Verify that the version of of VyOS is VyOS 1.4-rolling-202303170317 or later
set system sflow interface eth0
set system sflow interface eth1
set system sflow interface eth2
set system sflow polling 30
set system sflow sampling-rate 1000
set system sflow server 10.0.0.30 port 6343
The above commands configure sFlow export in the VyOS CLI using the embedded Host sFlow agent.
docker run --name sflow-rt -p 8008:8008 -p 6343:6343/udp -d sflow/prometheus
A quick way to experiment with sFlow is to run the pre-built sflow/prometheus image using Docker on the sFlow server (in this case on 10.0.0.30). The chart at the top of the page uses the Flow Browser application to display an up to the second view of the largest tcp flows through the VyOS router, click on this link to open the application with the settings shown.
Flow metrics with Prometheus and Grafana describes how integrate flow analytics into operational dashboards.
DDoS protection quickstart guide describes how to use real-time sFlow analytics with BGP Flowspec / RTBH to automatically mitigate DDoS attacks.

Saturday, March 11, 2023

VyOS

VyOS is an open source router operating system based on Linux. This article discusses how to improve network traffic visibility on VyOS based routers using the open source Host sFlow agent.

VyOS claims sFlow support, so why is it necessary to install an alternative sFlow agent? The following experiment demonstrates that there are significant issues with the VyOS sFlow implementation.

vyos@vyos:~$ show version
Version:          VyOS 1.4-rolling-202301260317
Release train:    current

Built by:         autobuild@vyos.net
Built on:         Thu 26 Jan 2023 03:17 UTC
Build UUID:       a95385b7-12f9-438d-b49c-b91f47ea7ab7
Build commit ID:  d5ea780295ef8e

Architecture:     x86_64
Boot via:         installed image
System type:      KVM guest

Hardware vendor:  innotek GmbH
Hardware model:   VirtualBox
Hardware S/N:     0
Hardware UUID:    6988d219-49a6-0a4a-9413-756b0395a73d

Copyright:        VyOS maintainers and contributors
Install a recent version of VyOS under VirtualBox and configure routing between two Linux virtual machines connected to eth1 and eth2 on the router. Out of band management is configured on eth0.
set system flow-accounting disable-imt
set system flow-accounting sflow agent-address 10.0.0.50
set system flow-accounting sflow sampling-rate 1000
set system flow-accounting sflow server 10.0.0.30 port 6343
set system flow-accounting interface eth0
set system flow-accounting interface eth1
set system flow-accounting interface eth2
The above commands configure sFlow monitoring on VyOS using the native sFlow agent.
The sflow/sflow-test tool is used to test the sFlow implementation while generating traffic consisting of a series of iperf3 tests (each generating approximately 50Mbps). The test fails in a number of significant ways:
  1. The implementation of sFlow is incomplete, omitting required interface counter export
  2. The peak traffic reported (3Mbps) is a fraction of the traffic generated by iperf3
  3. There is an inconsistency in the packet size reported in the sFlow messages
  4. Tests comparing counters and flow data fail because of missing counter export (1)
Fortunately, VyOS is a Linux based operating system, so we can install the Host sFlow agent as an alternative to the native sFlow implementation to provide traffic visibility.
delete system flow-accounting
First, disable the native VyOS sFlow agent.
wget https://github.com/sflow/host-sflow/releases/download/v2.0.38-1/hsflowd-ubuntu20_2.0.38-1_amd64.deb
sudo dpkg -i hsflowd-ubuntu20_2.0.38-1_amd64.deb
Next, download and install the Host sFlow agent by typing the above commands in VyOS shell.
# hsflowd configuration file
# http://sflow.net/host-sflow-linux-config.php

sflow {
  collector { ip=10.0.0.30 }
  pcap { dev = eth0 }
  pcap { dev = eth1 }
  pcap { dev = eth2 }
}
Edit the /etc/hsflowd.conf file.
systemctl restart hsflowd
Restart the sFlow agent to pick up the new configuration.
Rerunnig sflow-test shows that the implementation now passes. The peaks shown in the trend graph are consistent with the traffic generated by iperf3 and with traffic levels reported in interface counters.
The sflow/sflow-test Docker image also includes the Flow Browser application that can be used to monitor traffic flows in real-time. The screen shot above shows traffic from a single iperf3 test.
The sflow/sflow-test Docker image also includes the Metric Browser application that can be used to monitor counters in real-time. The screen shot above shows cpu_utilization.

The sFlow Test, Browse Flows and Browse Metrics applications run on the sFlow-RT analytics engine. Additional examples include Flow metrics with Prometheus and Grafana and DDoS protection quickstart guide.

Tuesday, August 23, 2022

NVIDIA ConnectX SmartNICs

NVIDIA ConnectX SmartNICs offer best-in-class network performance, serving low-latency, high-throughput applications with one, two, or four ports at 10, 25, 40, 50, 100, 200, and up to 400 gigabits per second (Gb/s) Ethernet speeds.

This article describes how use the instrumentation built into ConnectX SmartNICs for data center wide network visibility. Real-time network telemetry for automation provides some background, giving an overview of the sFlow industry standard with an example of troubleshooting a high performance GPU compute cluster.

Linux as a network operating system describes how standard Linux APIs are used in NVIDIA Spectrum switches to monitor data center network performance. Linux Kernel Upstream Release Notes v5.19 describes recent driver enhancements for ConnectX SmartNICs that extend visibility to servers for end-to-end visibility into the performance of high performance distributed compute infrastructure.

The open source Host sFlow agent uses standard Linux APIs to configure instrumentation in switches and hosts, streaming the resulting measurements to analytics software in real-time for comprehensive data center wide visibility.

Packet sampling provides detailed visibility into traffic flowing across the network. Hardware packet sampling makes it possible to monitor 400 gigabits per second interfaces on the server at line rate with minimal CPU/memory overhead.
psample { group=1 egress=on }
dent { sw=off switchport=^eth[0-9]+$ }
The above Host sFlow configuration entries enable packet sampling on the host. Linux 4.11 kernel extends packet sampling support describes the Linux PSAMPLE netlink channel used by the network adapter to send packet samples to the Host sFlow agent. The dent module automatically configures hardware packet sampling on network interfaces matching the switchport pattern (eth0, eth1, .. in this example) using the Linux tc-sample API, directing the packet samples to be sent to the specified psample group. 
Visibility into dropped packets offers significant benefits for network troubleshooting, providing real-time network-wide visibility into the specific packets that were dropped as well the reason the packet was dropped. This visibility instantly reveals the root cause of drops and the impacted connections.
dropmon { group=1 start=on sw=on hw=on }
The above Host sFlow configuration entry enables hardware dropped packet monitoring on the network adapter hardware.
sflow {
  collector { ip=10.0.0.1 }
  psample { group=1 egress=on }
  dropmon { group=1 start=on sw=on hw=on }
  dent { sw=off switchport=^eth[0-9]+$ }
}
The above /etc/hsflowd.conf file shows a complete configuration. The centralized collector, 10.0.0.1, receives sFlow from all the servers and switches in the network to provide comprehensive end-to-end visibility.
The sFlow-RT analytics engine receives and analyzes the sFlow telemetry stream, providing real-time analytics to visibility and automation systems (e.g. Flow metrics with Prometheus and Grafana).

Monday, February 28, 2022

Topology aware fabric analytics

Real-time telemetry from a 5 stage Clos fabric describes how to emulate and monitor the topology shown above using Containerlab and sFlow-RT. This article extends the example to demonstrate how topology awareness enhances analytics.
docker run --rm -it --privileged --network host --pid="host" \
  -v /var/run/docker.sock:/var/run/docker.sock -v /run/netns:/run/netns \
  -v ~/clab:/home/clab -w /home/clab \
  ghcr.io/srl-labs/clab bash
Start Containerlab.
curl -O https://raw.githubusercontent.com/sflow-rt/containerlab/master/clos5.yml
Download the Containerlab topology file.
sed -i "s/prometheus/topology/g" clos5.yml
Change the sFlow-RT image from sflow/prometheus to sflow/topology in the Containerlab topology. The sflow/topology image packages sFlow-RT with useful applications that combine topology awareness with analytics.
containerlab deploy -t clos5.yml
Deploy the topology.
curl -O https://raw.githubusercontent.com/sflow-rt/containerlab/master/clos5.json
Download the sFlow-RT topology file.
curl -X PUT -H "Content-Type: application/json" -d @clos5.json \
http://localhost:8008/topology/json
Post the topology to sFlow-RT.
Connect to the sFlow-RT Topology application, http://localhost:8008/app/topology/html/. The dashboard confirms that all the links and nodes in the topology are streaming telemetry. There is currently no traffic on the network, so none of the nodes in the topology are sending flow data.
docker exec -it clab-clos5-h1 iperf3 -c 172.16.4.2
Generate traffic. You should see the Nodes No Flows number drop as switches in the traffic path stream flow data. In a production network traffic flows through all the switches and so all switches will be streaming flow telemetry.
Click on the Locate tab and enter the address 172.16.4.2. Click submit to find the location of the address. Topology awareness allows sFlow-RT to examine streaming flow data from all the links in the network and determine switch ports and MAC addresses associated with the point of ingress into the fabric.
Connect to the sFlow-RT Fabric Metrics application, http://localhost:8008/app/fabric-metrics/html/. The Traffic charts identifies each iperf3 test as a large (elephant) flow - see SDN and large flows for a discussion of the importance of large flow visibility. The Busy Links chart reports the number of links in the topology with a utilization exceeding a threshold (in this case 80% utilization).
The Ports tab contains charts showing switch ports with the highest ingress/egress utilization, packet discards, and packet errors.
Connect to the sFlow-RT Trace Flow application,  http://localhost:8008/app/trace-flow/html/.
ipsource=172.16.1.2
Enter a traffic filter and click Submit.
docker exec -it clab-clos5-h1 iperf3 -c 172.16.4.2
Run an iperf3 test and the path the traffic takes across the network topology will be immediately displayed.
Connect to the sFlow-RT Flow Browser application, http://localhost:8008/app/browse-flows/html/index.html?keys=ipsource&value=bps. Run a sequence of iperf3 tests and the traffic will be immediately shown. Defining Flows describes flow attributes that can be added to the query to examine inner / outer tunneled traffic, VxLAN, MPLS, GRE, etc.

Trace Flow demonstrated that flow telemetry is streamed by each switch port along the path from source to destination host to deliver end-to-end visibility. Simply summing the data would overestimate the size of the flow. Adding topology information allows sFlow-RT to intelligently combine data, eliminating duplicate measurements, to provide accurate measurements of traffic crossing the fabric.

containerlab destroy -t clos5.yml
When you are finished, run the above command to stop the containers and free the resources associated with the emulation.

Moving the monitoring solution from Containerlab to production is straightforward since sFlow is widely implemented in datacenter equipment from vendors including: A10, Arista, Aruba, Cisco, Edge-Core, Extreme, Huawei, Juniper, NEC, Netgear, Nokia, NVIDIA, Quanta, and ZTE. In addition, the open source Host sFlow agent makes it easy to extend visibility beyond the physical network into the compute infrastructure.

Monday, February 21, 2022

Real-time telemetry from a 5 stage Clos fabric

CONTAINERlab described how to use FRRouting and Host sFlow in a Docker container to emulate switches in a Clos (leaf/spine) fabric. The recently released open source project, https://github.com/sflow-rt/containerlab, simplifies and automates the steps needed to build and monitor topologies.
docker run --rm -it --privileged --network host --pid="host" \
  -v /var/run/docker.sock:/var/run/docker.sock -v /run/netns:/run/netns \
  -v ~/clab:/home/clab -w /home/clab \
  ghcr.io/srl-labs/clab bash
Run the above command to start Containerlab if you already have Docker installed; the ~/clab directory will be created to persist settings. Otherwise, Installation provides detailed instructions for a variety of platforms.
curl -O https://raw.githubusercontent.com/sflow-rt/containerlab/master/clos5.yml
Next, download the topology file for the 5 stage Clos fabric shown at the top of this article.
containerlab deploy -t clos5.yml
Finally, deploy the topology.
Note: The 3 stage Clos topology, clos3.yml, described in the previous article is also available.
The initial launch may take a couple of minutes as the container images are downloaded for the first time. Once the images are downloaded, the topology deploys in around 10 seconds.
An instance of the sFlow-RT real-time analytics engine receives industry standard sFlow telemetry from all the switches in the network. All of the switches in the topology are configured to send sFlow to the sFlow-RT instance. In this case, Containerlab is running the pre-built sflow/prometheus image which packages sFlow-RT with useful applications for exploring the data.
Connect to the web interface, http://localhost:8008. The sFlow-RT dashboard verifies that telemetry is being received from 10 agents (the 10 switches in the Clos fabric). See the sFlow-RT Quickstart guide for more information.
The screen capture shows a real-time view of traffic flowing across the network during a series iperf3 tests. Click on the sFlow-RT Apps menu and select the browse-flows application, or click here for a direct link to a chart with the settings shown above.
docker exec -it clab-clos5-h1 iperf3 -c 172.16.4.2
Each of the hosts in the network has an iperf3 server, so running the above command will test bandwidth between h1 and h4.
docker exec -it clab-clos5-leaf1 vtysh
Linux with open source routing software (FRRouting) is an accessible alternative to vendor routing stacks (no registration / license required, no restriction on copying means you can share images on Docker Hub, no need for virtual machines).  FRRouting is popular in production network operating systems (e.g. Cumulus Linux, SONiC, DENT, etc.) and the VTY shell provides an industry standard CLI for configuration, so labs built around FRR allow realistic network configurations to be explored.
containerlab destroy -t clos5.yml
When you are finished, run the above command to stop the containers and free the resources associated with the emulation.

Moving the monitoring solution from Containerlab to production is straightforward since sFlow is widely implemented in datacenter equipment from vendors including: A10, Arista, Aruba, Cisco, Edge-Core, Extreme, Huawei, Juniper, NEC, Netgear, Nokia, NVIDIA, Quanta, and ZTE. In addition, the open source Host sFlow agent makes it easy to extend visibility beyond the physical network into the compute infrastructure.