TATA Consultancy Services white paper, Actionable Intelligence in the SDN Ecosystem: Optimizing Network Traffic through FRSA, demonstrates how real-time traffic analytics and SDN can be combined to perform real-time traffic engineering of large flows across a WAN infrastructure.
The architecture being demonstrated is shown in the diagram (this diagram has been corrected - the diagram in the white paper incorrectly states that sFlow-RT analytics software uses a REST API to poll the nodes in the topology. In fact, the nodes stream telemetry using the widely supported, industry standard, sFlow protocol, providing real-time visibility and scaleability that would be difficult to achieve using polling - see Push vs Pull).
The load balancing application receives real-time notifications of large flows from the sFlow-RT analytics software and programs the SDN Controller (in this case OpenDaylight) to push forwarding rules to the switches to direct the large flows across a specific path. Flow Aware Real-time SDN Analytics (FRSA) provides an overview of the basic ideas behind large flow traffic engineering that inspired this use case.
While OpenDaylight is used in this example, an interesting alternative for this use case would be the ONOS SDN controller running the Segment Routing application. ONOS is specifically designed with carriers in mind and segment routing is a natural fit for the traffic engineering task described in this white paper.
Leaf and spine traffic engineering using segment routing describes a demonstration combining real-time analytics and SDN control in a data center context. The demonstration was part of the recent 2015 Open Networking Summit (ONS) conference Showcase and presented in the talk, CORD: FABRIC An Open-Source Leaf-Spine L3 Clos Fabric, by Saurav Das.
Thursday, June 25, 2015
Sunday, June 21, 2015
Optimizing software defined data center
The recent Fortune magazine article, Software-defined data center market to hit $77.18 billion by 2020, starts with the quote "Data centers are no longer just about all the hardware gear you can stitch together for better operations. There’s a lot of software involved to squeeze more performance out of your hardware, and all that software is expected to contribute to a burgeoning new market dubbed the software-defined data center."
The recent ONS2015 Keynote from Google's Amin Vahdat describes how Google builds large scale software defined data centers. The presentation is well worth watching in its entirety since Google has a long history of advancing distributed computing with technologies that have later become mainstream.
There are a number of points in the presentation that relate to the role of networking to the performance of cloud applications. Amin states, "Networking is at this inflection point and what computing means is going to be largely determined by our ability to build great networks over the coming years. In this world data center networking in particular is a key differentiator."
This slide shows the the large pools of storage and compute connected by the data center network that are used to deliver data center services. Amin states that the dominant costs are compute and storage and that the network can be relatively inexpensive.
The key to an efficient data center is balance. If a resource is scarce, then other resources are left idle and this increases costs and limits the overall value of the data center. Amin goes on to state, "Typically the resource that is most scarce is the network."
The need to build large scale high-performance networks has driven Google to build networks with the following properties:
Here again Google is leading the overall network market transition to inexpensive leaf and spine networks built using commodity hardware.
Google is not alone in leading this trend. Facebook has generated significant support for the Open Compute Project (OCP), which publishes open source designs data center equipment, including merchant silicon based leaf and spine switches. A key OCP project is the Open Network Install Environment (ONIE), which allows third party software to be installed on the network equipment. ONIE separates hardware from software and has spawned a number of innovative networking software companies, including: Cumulus Networks, Big Switch Networks, Pica8, Pluribus Networks. Open network hardware and the related ecosystem of software is entering the mainstream as leading vendors such as Dell and HP deliver open networking hardware, software and support to enterprise customers.
The ONS2015 keynote from AT&T's John Donovan, describes the economic drivers for AT&T's transition to open networking and compute architectures.
John discusses the rapid move from legacy TDM (Time Division Multiplexing) technologies to commodity Ethernet, explaining that "video now makes up the majority of traffic on our network." This is a fundamental shift for AT&T and John states that "We plan to virtualize and control more than 75% of our network using cloud infrastructure and a software defined architecture."
John mentions the CORD (Central Office Re-architected as a Datacenter) project which proposes an architecture very similar to Google's, consisting of a leaf and spine network built using open merchant silicon based hardware connecting commodity servers and storage. A prototype of the CORD leaf and spine network was shown as part of the ONS2015 Solutions Showcase.
Leaf and spine traffic engineering using segment routing and SDN describes a live demonstration presented in ONS2015 Solutions Showcase. The demonstration shows how centralized analytics and control can be used to optimize the performance of commodity leaf and spine networks handling the large "Elephant" flows that typically comprise most traffic on the network (for example, video streams - see SDN and large flows for a general discussion).
Getting back to the Fortune article, it is clear that the move to open commodity network, server and storage hardware shifts value from hardware to the software solutions that optimize performance. The network in particular is a critical resource that constrains overall performance and network optimization solutions can provide disproportionate benefits by eliminating bottlenecks that constrain compute and storage and limit the value delivered by the data center.
The recent ONS2015 Keynote from Google's Amin Vahdat describes how Google builds large scale software defined data centers. The presentation is well worth watching in its entirety since Google has a long history of advancing distributed computing with technologies that have later become mainstream.
This slide shows the the large pools of storage and compute connected by the data center network that are used to deliver data center services. Amin states that the dominant costs are compute and storage and that the network can be relatively inexpensive.
In Overall Data Center Costs James Hamilton breaks down the monthly costs of running a data center and puts the cost of network equipment at 8% of the overall cost.However, Amin goes on to explain why networking has a disproportionate role in the overall value delivered by the data center.
The key to an efficient data center is balance. If a resource is scarce, then other resources are left idle and this increases costs and limits the overall value of the data center. Amin goes on to state, "Typically the resource that is most scarce is the network."
The need to build large scale high-performance networks has driven Google to build networks with the following properties:
- Leaf and Spine (Clos) topology
- Merchant silicon based switches (white box / brite box / bare metal)
- Centralized control (SDN)
Here again Google is leading the overall network market transition to inexpensive leaf and spine networks built using commodity hardware.
Google is not alone in leading this trend. Facebook has generated significant support for the Open Compute Project (OCP), which publishes open source designs data center equipment, including merchant silicon based leaf and spine switches. A key OCP project is the Open Network Install Environment (ONIE), which allows third party software to be installed on the network equipment. ONIE separates hardware from software and has spawned a number of innovative networking software companies, including: Cumulus Networks, Big Switch Networks, Pica8, Pluribus Networks. Open network hardware and the related ecosystem of software is entering the mainstream as leading vendors such as Dell and HP deliver open networking hardware, software and support to enterprise customers.
John discusses the rapid move from legacy TDM (Time Division Multiplexing) technologies to commodity Ethernet, explaining that "video now makes up the majority of traffic on our network." This is a fundamental shift for AT&T and John states that "We plan to virtualize and control more than 75% of our network using cloud infrastructure and a software defined architecture."
John mentions the CORD (Central Office Re-architected as a Datacenter) project which proposes an architecture very similar to Google's, consisting of a leaf and spine network built using open merchant silicon based hardware connecting commodity servers and storage. A prototype of the CORD leaf and spine network was shown as part of the ONS2015 Solutions Showcase.
![]() |
| ONS2015 Solutions Showcase: Open-source spine-leaf Fabric |
Getting back to the Fortune article, it is clear that the move to open commodity network, server and storage hardware shifts value from hardware to the software solutions that optimize performance. The network in particular is a critical resource that constrains overall performance and network optimization solutions can provide disproportionate benefits by eliminating bottlenecks that constrain compute and storage and limit the value delivered by the data center.
Labels:
data center,
ECMP,
Ethernet,
SDN
Friday, June 12, 2015
Leaf and spine traffic engineering using segment routing and SDN
The short 3 minute video is a live demonstration showing how software defined networking (SDN) can be used to orchestrate the measurement and control capabilities of commodity data center switches to automatically load balance traffic on a 4 leaf, 4 spine, 10 Gigabit leaf and spine network.
The diagram shows the physical layout of the demonstration rack. The four logical racks with their servers and leaf switches are combined in a single physical rack, along with the spine switches, and SDN controllers. All the links in the data plane are 10G and sFlow has been enabled on every switch and link with the following settings, packet sampling rate 1-in-8192 and counter polling interval 20 seconds. The switches have been configured to send the sFlow data to sFlow-RT analytics software running on Controller 1.
The switches are also configured to enable OpenFlow 1.3 and connect to multiple controllers in the redundant ONOS SDN controller cluster running on Controller 1 and Controller 2.
The charts from The Nature of Datacenter Traffic: Measurements & Analysis show data center traffic measurements published by Microsoft. Most traffic flows are short duration. However, combined they consume less bandwidth than a much smaller number of large flows with durations ranging from 10 seconds to 100 seconds. The large number of small flows are often referred to as "Mice" and the small number of large flows as "Elephants."
This demonstration focuses on the Elephant flows since they consume most of the bandwidth. The iperf load generator is used to generate two streams of back to back 10Gbyte transfers that should take around 8 seconds to complete over the 10Gbit/s leaf and spine network.
while true; do iperf -B 10.200.3.32 -c 10.200.3.42 -n 10000M; done
while true; do iperf -B 10.200.3.33 -c 10.200.3.43 -n 10000M; doneThese two independent streams of connections from switch 103 to 104 drive the demo.
The HTML 5 dashboard queries sFlow-RT's REST API to extract and display real-time flow information.
The dashboard shows a topological view of the leaf and spine network in the top left corner. Highlighted "busy" links have a utilization of over 70% (i.e. 7Gbit/s). The topology shows flows taking independent paths from 103 to 104 (via spines 105 and 106). The links are highlighted in blue to indicate that the utilization on each link is driven by a single large flow. The chart immediately under the topology trends the number of busy links. The most recent point, to the far right of the chart, has a value of 4 and is colored blue, recording that 4 blue links are shown in the topology.
The bottom chart trends the total traffic entering the network broken out by flow. The current throughput is just under 20Gbit/s and is comprised of two roughly equal flows.
The ONOS controller configures the switches to forward packets using Equal Cost Multi-Path (ECMP) routing. There are four equal cost (hop count) paths from leaf switch 103 to leaf switch 104 (via spine switches 105, 106, 107 and 108). The switch hardware selects between paths based on a hash function calculated over selected fields in the packets (e.g. source and destination IP addresses + source and destination TCP ports), e.g.
index = hash(packet fields) % group.size selected_physical_port = group[index]Hash based load balancing works well for large numbers of Mice flows, but is less suitable for the Elephant flows. The hash function may assign multiple Elephant flows to the same path resulting in congestion and poor network performance.
This screen shot shows the effect of a collision between flows. Both flows have been assigned the same path via spine switch 105. The analytics software has determined that there are multiple large flows on the pair of busy links and indicates this by coloring the highlighted links yellow. The most recent point, to the far right of the upper trend chart, has a value of 2 and is colored yellow, recording that 2 yellow links are shown in the topology.
Notice that the bottom chart shows that the total throughput has dropped to 10Gbit/s and that each of the flows is limited to 5Gbit/s - halving the throughput and doubling the time taken to complete the data transfer.
The dashboard demonstrates that the sFlow-RT analytics engine has all the information needed to characterize the problem - identifying busy links and the large flows. What is needed is a way to take action to direct one of the flows on a different path across the network.
This is where the segment routing functionality of the ONOS SDN controller comes into its own. The controller implements Segment Routing in Networking (SPRING) as the method of ECMP forwarding and provides a simple REST API for specifying paths across the network and assigning traffic to those paths.
In this example, the traffic is colliding because both flows are following a path running through spine switch 105. Paths from leaf 103 to 104 via spines 106, 107 or 108 have available bandwidth.
The following REST operation instructs the segment routing module to build a path from 103 via 106 to 104:
curl -H "Content-Type: application/json" -X POST http://localhost:8181/onos/segmentrouting/tunnel -d '{"tunnel_id":"t1", "label_path":[103,106,104]}'
Once the tunnel has been defined, the following REST operation assigns one of the colliding flows to the new path:
curl -H "Content-Type: application/json" -X POST http://localhost:8181/onos/segmentrouting/policy -d '{"policy_id":"p1", "priority":1000, "src_ip":"10.200.3.33/32", "dst_ip":"10.200.4.43/32", "proto_type":"TCP", "src_tp_port":53163, "dst_tp_port":5001, "policy_type":"TUNNEL_FLOW", "tunnel_id":"t1"}'
However, manually implementing these controls isn't feasible since there is a constant stream of flows that would require policy changes every few seconds.The final screen shot shows the result of enabling the Flow Accelerator application on sFlow-RT. Flow Accelerator watches for collisions and automatically applies and removes segment routing policies as required to separate Elephant flows, in this case the table on the top right of the dashboard shows that a single policy has been installed sending one of the flows via spine 107.
The controller has been running for about half the interval show in the two trend charts (approximately two and half minutes). To the left you can see frequent long collisions and consequent dips in throughput. To the right you can see that more of the links are kept busy and flows experience consistent throughput.
Traffic analytics are a critical component of this demonstration. Why does this demonstration use sFlow? Could NetFlow/JFlow/IPFIX/OpenFlow etc. be used instead? The above diagram illustrates the basic architectural difference between sFlow and other common flow monitoring technologies. For this use case the key difference is that with sFlow real-time data from the entire network is available in a central location (the sFlow-RT analytics software), allowing the traffic engineering application to make timely load balancing decisions based on complete information. Rapidly detecting large flows, sFlow vs. NetFlow/IPFIX presents experimental data to demonstrate the difference is responsiveness between sFlow and the other flow monitoring technologies. OK, but what about using hardware packet counters periodically pushed via sFlow, or polled using SNMP or OpenFlow? Here again, measurement delay limits the usefulness of the counter information for SDN applications, see Measurement delay, counters vs. packet samples. Fortunately, the requirement for sFlow is not limiting since support for standard sFlow measurement is built into most vendor and white box hardware - see Drivers for growth.
Finally, the technologies presented in this demonstration have broad applicability beyond the leaf and spine use case. Elephant flows dominate data center, campus, wide area, and wireless networks (see SDN and large flows). In addition, segment routing is applicable to wide area networks as was demonstrated by an early version of the ONOS controller (Prototype & Demo Videos). The demonstration illustrates that the integration real-time sFlow analytics in SDN solutions enables fundamentally new use cases that drive SDN to a new level - optimizing networks rather than simply provisioning them.
Labels:
data center,
ECMP,
ONOS,
SDN,
segment routing,
sFlow,
sFlow-RT,
SPRING
Monday, May 18, 2015
Analytics and SDN
Recent presentations from AT&T and Google describe SDN/NFV architectures that incorporate measurement based feedback in order to improve performance and reliability.
The first slide is from a presentation by AT&T's Margaret Chiosi; SDN+NFV Next Steps in the Journey, NFV World Congress 2015. The future architecture envisions generic (white box) hardware providing a stream of analytics which are compared to policies and used to drive actions to assure service levels.
The second slide is from the presentation by Google's Bikash Koley at the Silicon Valley Software Defined Networking Group Meetup. In this architecture, "network state changes observed by analyzing comprehensive time-series data stream." Telemetry is used to verify that the network is behaving as intended, identifying policy violations so that the management and control planes can apply corrective actions. Again, the software defined network is built from commodity white box switches.
Support for standard sFlow measurements is almost universally available in commodity switch hardware. sFlow agents embedded within network devices continuously stream measurements to the SDN controller, supplying the analytics component with the comprehensive, scaleable, real-time visibility needed for effective control.
SDN fabric controller for commodity data center switches describes the measurement and control capabilities available in commodity switch hardware. In addition, there are a number of use cases described on this blog that demonstrate the benefits of incorporating traffic analytics in SDN solutions, including:
While the incorporation of telemetry / analytics in SDN architectures is recent, the sFlow measurement standard is a proven technology that has been incorporated in switch ASICs for over a decade. Incorporating sFlow in SDN solution stacks leverages the capabilities of commodity switches to provide immediate visibility into operational networks without the complexity and cost of adding probes or being locked in to vendor specific hardware.
The first slide is from a presentation by AT&T's Margaret Chiosi; SDN+NFV Next Steps in the Journey, NFV World Congress 2015. The future architecture envisions generic (white box) hardware providing a stream of analytics which are compared to policies and used to drive actions to assure service levels.
The second slide is from the presentation by Google's Bikash Koley at the Silicon Valley Software Defined Networking Group Meetup. In this architecture, "network state changes observed by analyzing comprehensive time-series data stream." Telemetry is used to verify that the network is behaving as intended, identifying policy violations so that the management and control planes can apply corrective actions. Again, the software defined network is built from commodity white box switches.
Support for standard sFlow measurements is almost universally available in commodity switch hardware. sFlow agents embedded within network devices continuously stream measurements to the SDN controller, supplying the analytics component with the comprehensive, scaleable, real-time visibility needed for effective control.
SDN fabric controller for commodity data center switches describes the measurement and control capabilities available in commodity switch hardware. In addition, there are a number of use cases described on this blog that demonstrate the benefits of incorporating traffic analytics in SDN solutions, including:
While the incorporation of telemetry / analytics in SDN architectures is recent, the sFlow measurement standard is a proven technology that has been incorporated in switch ASICs for over a decade. Incorporating sFlow in SDN solution stacks leverages the capabilities of commodity switches to provide immediate visibility into operational networks without the complexity and cost of adding probes or being locked in to vendor specific hardware.
Labels:
control,
measurement,
NFV,
SDN
Wednesday, April 1, 2015
Big Tap sFlow: Enabling Pervasive Flow-level Visibility
Today's Big Switch Networks webinar, Big Tap sFlow: Enabling Pervasive Flow-level Visibility, describes how Big Switch uses software defined networking (SDN) to control commodity switches and deliver network visibility. The webinar presents a live demonstration showing how real-time sFlow analytics is used to automatically drive SDN actions to provide a "smarter way to find a needle in a haystack."
The video presentation covers the following topics:
- 0:00 Introduction to Big Tap
- 7:00 sFlow generation and use cases
- 12:30 Demonstration of real-time tap triggering based on sFlow
The webinar describes how the network wide monitoring provided by industry standard sFlow instrumentation complements the Big Tap SDN controller's ability to capture and direct packet selected packet streams to visibility tools.
The above slide from the webinar draws an analogy for the role that sFlow plays in targeting the capture network to that of a finderscope, the small, wide-angle telescope used to provide an overview of the sky and guide the telescope to its target. Support for the sFlow measurement standard is built into commodity switch hardware and is enabled on all ports in the capture network to provide a wide angle view of all traffic in the data center. Once suspicious activity is detected, targeted captures can be automatically triggered using Big Tap's REST API.
Black lists can be very large, larger lists can exceed a million addresses. Switches don't have the resources to match traffic against such large lists. However, sFlow shifts analysis from the switches to external software which can easily handle to task of matching traffic against large lists. The live demonstration uses InMon's sFlow-RT real-time analytics software to match sFlow data against a large blacklist. When a match is detected the Big Tap controller is programmed via a REST API call to capture all the packets from the suspected hosts and stream them to Wireshark for further investigation.
Monday, March 23, 2015
OpenNetworking.tv interview
The OpenNetworking.tv interview includes a wide ranging discussion of current trends in the software defined networking (SDN), including: merchant silicon, analytics, probes, scaleability, Open vSwitch, network virtualization, VxLAN, network function virtualization (NFV), Open Compute Project, white box / bare metal switches, leaf and spine topologies, large "Elephant" flow marking and steering, Cumulus Linux, Big Switch, orchestration, Puppet and Chef.
The interview and full transcript are available on SDxCentral: sFlow Creator Peter Phaal On Taming The Wilds Of SDN & Virtual Networking
Related articles on this blog include:
Labels:
data center,
NFV,
SDN,
sFlow
Friday, March 13, 2015
ECMP visibility with Cumulus Linux
Topology discovery with Cumulus Linux looked at an alternative Multi-Chassis Link Aggregation (MLAG) configuration and shows how to extract the configuration and monitor traffic on the network using sFlow and Fabric View.
The paper Hedera: Dynamic Flow Scheduling for Data Center Networks describes the impact of colliding flows on effective ECMP cross sectional bandwidth. The paper gives an example which demonstrates that effective cross sectional bandwidth can be reduced by a factor of between 20% to 60%, depending on the number of simultaneous flows per host.
This article uses the workbench to demonstrate the effect of large "Elephant" flow collisions on network throughput. The following script running on each of the servers uses the iperf tool to generate pairs of overlapping Elephant flows:
cumulus@server1:~$ while true; do iperf -c 10.4.2.2 -t 20; sleep 20; done
------------------------------------------------------------
Client connecting to 10.4.2.2, TCP port 5001
TCP window size: 1.06 MByte (default)
------------------------------------------------------------
[ 3] local 10.4.1.2 port 57234 connected with 10.4.2.2 port 5001
[ ID] Interval Transfer Bandwidth
[ 3] 0.0-20.0 sec 21.9 GBytes 9.41 Gbits/sec
------------------------------------------------------------
Client connecting to 10.4.2.2, TCP port 5001
TCP window size: 1.06 MByte (default)
------------------------------------------------------------
[ 3] local 10.4.1.2 port 57240 connected with 10.4.2.2 port 5001
[ ID] Interval Transfer Bandwidth
[ 3] 0.0-20.0 sec 10.1 GBytes 4.34 Gbits/sec
------------------------------------------------------------
Client connecting to 10.4.2.2, TCP port 5001
TCP window size: 1.06 MByte (default)
------------------------------------------------------------
[ 3] local 10.4.1.2 port 57241 connected with 10.4.2.2 port 5001
[ ID] Interval Transfer Bandwidth
[ 3] 0.0-20.0 sec 21.9 GBytes 9.41 Gbits/sec
------------------------------------------------------------
The first iperf test achieves a TCP throughput of 9.41 Gbits/sec (the maximum achievable on the 10Gbit/s network in the workbench). However, the second test only achieves a throughput of 4.34 Gbits/sec. How can this result be explained?The Top Flows table above confirms that two simultaneous elephant flows are being tracked by Fabric View.
The Traffic charts update every second and give a fine grained view of the traffic flows over time. The charts clearly show how iperf flows vary in throughput, with the low throughput runs achieving a throughput of approximately 50% of the network capacity (these results are consistent with 20% to 60% reported in the Hedera paper).
The Performance charts show what is happening. Packets take two hops as they are routed from leaf1 to leaf2 (via spine1 or spine2). Each iperf connection is able to fully utilize the two links to achieve line rate throughput. Comparing the Total Traffic and Busy Spine Links charts shows that peak total throughput of approximately 20Gbits/sec corresponds to interval when 4 spine links are busy. The throughput is halved during intervals when the routes overlap and share 1 or 2 links (shown in gold as Collisions on the Busy Spine Links chart).
Readers might be surprised by the frequency of collisions given the number of links in the network. Packets take two hops to go from leaf1 to leaf2 - routed via spine1 or spine2. In addition, the links between switches are paired, so there are 8 possible two hop paths from leaf1 to leaf2. The explanation involves looking at the conditional probability that the second flow with overlap with the first. Suppose the first flow takes is routed to spine1 via port swp1s0 and that spine1 routes the flow to leaf2 via port swp51. If the second flow is routed via any of the 4 paths through spine2, there is no collision. However, if it is routed via spine1, there is only 1 path that avoids collisions (leaf1 port swp1s1 to spine1 port swp52). This means that there is a 5 / 8 chance of avoiding a collision, or a 3/8 (37.5%) chance that the two flow will collide. The probability of flow collisions is surprisingly high even on very large networks with many spine switches and paths (see Birthday Paradox).Also note the Discards trend in the Congestion and Errors section. Comparing the rate of discards with Collisions in the Busy Spine Links chart shows that discards don't occur unless there are Elephant flow collisions on the busy links.
The Discard trend lags the Collision trend because discards are reported using sFlow counters and the Collision metric are based on packet samples - see Measurement delay, counters vs. packet samplesThis example demonstrates the visibility into leaf and spine fabric performance achievable using standard sFlow instrumentation built into commodity switch hardware. If you have a leaf and spine network, request a free evaluation of Fabric View to better understand your network's performance.
This small four switch leaf and spine network is composed of 12 x 10 Gbits/sec links which would require 24 x 10 Gbits/sec taps with associated probes and collector to fully monitor using traditional tools used to monitor legacy data center networks. The cost and complexity of tapping leaf and spine topologies is prohibitive. However, leaf and spine switches typically include hardware support for the sFlow measurement standard, embedding line rate visibility into every switch port for network wide coverage at no extra cost. In this example, the Fabric View analytics software is running on a commodity physical or virtual server consuming 1% CPU and 200 MBytes RAM.Real-time analytics for leaf and spine networks is a core enabling technology for software defined networking (SDN) control mechanisms that can automatically adapt the network to rapidly changing flow patterns and dramatically improve performance.
For example, REST API for Cumulus Linux ACLs describes how and SDN controller can remotely control switches. Use cases discussed on this blog include: Elephant flow marking, Elephant flow steering, and DDoS mitigation.
Finally, Cumulus Linux runs on open switch hardware from Agema, Dell, Edge-Core, Penguin Computing, Quanta. In addition, Hewlett-Packard recently announced that they will soon be selling a new line of open network switches built by Accton Technologies and support Cumulus Linux. The increasing availability of low cost open networking hardware running Linux creates a platform for open source and commercial software developers to quickly build and deploy innovative solutions.
Labels:
data center,
ECMP,
sFlow,
topology,
visibility